inosakiInosakiinosaki

Contact Us
sales@365accountings.com   

CS81-N1112 Color Sensors – SICK Sensor

USD $ 303.66

SKU: 1028228

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1028228
Color Sensor Model: CS81-N1112
OEM Spec Ref 

Features

Dimensions (W x H x D)30.4 mm x 80 mm x 53 mm
Sensing distance12.5 mm 1)
Sensing distance tolerance± 3 mm
Housing design (light emission)Rectangular
Light sourceLED, RGB 2)
Wave length640 nm, 525 nm, 470 nm
Light spot size2 mm x 4 mm
Light spot directionVertical
AdjustmentTeach-in button
Teach-in modeStatic 1-point teach-in
  • 1) From front edge of lens.
  • 2) Average service life: 100,000 h at TU = +25 °C.

 

Mechanics/electronics

Supply voltage10 V DC … 30 V DC 1)
Ripple< 5 Vpp 2)
Current consumption< 120 mA 3)
Switching frequency

1 kHz 4)

3 kHz

6 kHz

Adjustable

Response time500 µs, 160 µs, 85 µs 5)
Switching outputNPN
Switching output (voltage)NPN: HIGH = approx. VS / LOW ≤ 2 V
Output (channel)1 color
Output current Imax.< 100 mA 6)
Input, teach-in (ET)

NPN

Teach: U < 2 V

Run: U = 10 V … < UV

Input, blanking input (AT)

NPN

Blanked: U < 2 V

Free-running: U > 10 V … < Uv 7)

Retention time (ET)25 ms, non-volatile memory
Time delayDeactivation delay 20 ms, shiftable
Connection typeMale connector M12, 5-pin
Protection classII 8)
Circuit protection

UV connections, reverse polarity protected

Output Q short-circuit protected

Interference pulse suppression

Enclosure ratingIP67
Weight400 g
Housing materialMetal, zinc diecast
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) With light/dark ratio 1:1.
  • 5) Signal transit time with resistive load.
  • 6) Consumption count Q1 / Q2.
  • 7) AT > 200 µs.
  • 8) Reference voltage DC 32 V.

Title