inosakiInosakiinosaki

Contact Us
sales@365accountings.com   

DT500-A111 Long Range Distance Sensors – SICK Sensor

USD $ 2,490.81

SKU: N/A

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1026515
Distance Sensor Model:DT500-A111
OEM Spec Ref 

Mechanics/electronics

Supply voltage VsDC 10 V … 30 V, reverse polarity protected

UV ≥ DC 24 V for devices with heating

Ripple5 Vpp 1)
Power consumptionTyp. 3 W
Initialization time500 ms
Housing materialMetal (Aluminum die cast)
Window materialGlass
Connection typeMale connector, M12, 5-pin
Weight1,000 g
Dimensions (W x H x D)69 mm x 50 mm x 153 mm
Enclosure ratingIP65
Protection classII 2)
  • 1) May not fall short of or exceed VS tolerances.
  • 2) Reference voltage DC 32 V.

Performance

Measuring range0.2 m … 30 m, 90 % remission 1) 2)

0.8 m … 15 m, 6 % remission 1) 2)

TargetNatural objects
Resolution12 bit
Repeatability1 mm 3) 4)
Accuracy± 3 mm
Response time250 ms
Output time250 ms
Light sourceLaser, red 5)
visible red light
Laser class2, complies with 21 CFR 1040.10 and 1040.11 except for the conformance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1:2014, EN 60825-1:2014)
Typ. light spot size (distance)10 mm (at 7 m)

45 mm (at 30 m)

100 mm (at 70 m)

  • 1) In ambient light, max. 1 klx of constant light.
  • 2) Unique up to 150 m.
  • 3) 6 % … 90 % remission.
  • 4) Statistical error 1 σ.
  • 5) Average service life of 50,000 h at TA = +25 °C.

Interfaces

Analog output
Number1
TypeCurrent output
Current0 mA … 20 mA 1)
Multifunctional input (MF)> 12 V 2)
Laser-off input> 12 V
  • 1) Can be configured to the device: 0 mA … 20 mA / 4 mA … 20 mA (max. load resistance = Uv-2 V / 0.0205 A).
  • 2) Refer to function MF input.

Ambient data

Electromagnetic compatibility (EMC)EN 61000-6-2, EN 55011

EN 60947-5-7: 2003-9

Ambient temperature, operation–10 °C … +45 °C

–10 °C … +75 °C, operation with cooling case

Ambient temperature, storage–25 °C … +75 °C
Temperature driftTyp. 0.05 mm/K
Typ. Ambient light immunity≤ 3,000 lx
Mechanical loadShock: (EN 600 68-2-27 / –2-29)

Sine: (EN 600 68-2-6)

Noise: (EN 600 68-2-64)

Title

Go to Top