With a compact size of 150 x 166 x 62mm and a fan of 120mm in diameter, the ER-F Fan Type Ionizer belongs to the leading class of compact Fan Type Ionizers. The system employs a high-frequency AC method and boasts a +/-2kV discharge output voltage that discharges electrostatic contaminated objects quickly and safely. Louvers for long distance and wide area applications are shipped with the Ionizers. Standard fan types for faster charge removal times and low-volume types for discharging small parts or film are available.

Panasonic Fan Type Ionizer ER-F Series Features :

  • Straight And Angle Louvers Provided With The Ionizer
  • Easy Maintenance Of Discharge Needle
  • Safe Design
  • 24 V DC
  • No External, Compressed Air Necessary

For the Part Number not in our attribute selection, please contact us directly: sales@365accountings.com

The Panasonic Fan Type Ionizer ER-F Series Part Number :
ER-F12A,ER-F12SA

Data Sheet   |   Selection Guide

Two exchangeable louvers to suit your needs

Just simply replace the louver to change configuration between long distance and wide area ionization.

The two louvers come with the ionizer main body.

 

 

Equipped with discharge needle fouling detection function

Additionally equipped with discharge needle fouling detection function. When discharge becomes weak due to needle fouling, the DSC indicator will flash for notification

Remove the louver for effortless maintenance

Because the discharge needle unit is attached to the louver, exchange or maintenance of the needles is made easy without touching the main unit . A safe design where once the louver is removed, the high-voltage circuit and the fan will halt.

 

 

 

 

 

ORDER GUIDE

TypeCharge removal time (±1,000 V   ±100 V)Ion balanceModel No.
Standard fan type1 sec. approx. (Note 1)±10 V or less

(Note 2)

ER-F12A
Low-volume fan type1.5 sec. approx. (Note 1)ER-F12SA

Notes: 

1) Typical value at 200 mm 7.874 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.

2) Typical value at 300 mm 11.811 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.

 

Specifications

ItemSpecifications
CE marking compliant directivesEMC Directive, RoHS Directive
Charge removal time1.5 sec. approx.(±1,000 V → ±100 V)
(Note): Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
Ion balance±10 V or less
(Note): Typical value at 300 mm 11.811in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
Supply voltage24 V DC ±10%
Current consumption400 mA or less
Discharge methodHigh-frequency AC method
Discharge output voltage± 2 kV approx.
Main functionsError output, Discharge halt input
IndicatorsDischarge error (Red), Fan error (Red), Power (Green), Discharge (Green)
Ozone generation0.04 ppm or less
(Note): Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
Ambient temperature0℃ to +50℃ +32℉ to +122℉ (No dew condensation allowed),
Storage : -10℃ to +65℃ +14℉ to +149℉
Ambient humidity35% RH to 65% RH (No dew condensation allowed),
Storage : 35% RH to 65% RH
Grounding methodC (capacitor) grounding
MaterialEnclosure : ABS, Louver : ABS, Discharge needle unit : PBT, Discharge needle : Tungsten, Bracket : SPHC
WeightNew weight : 790 g approx.
AccessoriesStraight louver : 1 pc. (Note), Angle louver : 1 pc., Caution label : 1 set, Rubber cushion : 1 pc.
(Note): The discharge needle unit is loaded on the straight louver before shipment.
RemarkIf not specified, the ambient temperature for measurement is +20℃ +68℉.