inosakiInosakiinosaki

Contact Us
sales@365accountings.com   

IM30-15N-N-ZW0 Inductive Proximity Sensors – SICK Sensor

USD $ 84.84

SKU: 6021129

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6021129
Inductive proximity Sensor Model: IM30-15N-N-ZW0
OEM Spec Ref 

Features

HousingCylindrical thread design
Thread sizeM30 x 1.5
DiameterØ 30 mm
Sensing range Sn15 mm
Safe sensing range Sa12.15 mm
Installation typeNon-flush
Switching frequency200 Hz
Connection typeCable, 2-wire, 2 m
Switching outputNAMUR
Output functionNC
Enclosure ratingIP67 1)
Special applicationsExplosive areas
  • 1) According to EN 60529.

Mechanics/electronics

Supply voltage7.5 V DC … 25 V DC 1)
Current consumption30 mA 1)
Hysteresis1 % … 15 %
Temperature drift (of Sr)± 10 %
EMCAccording to EN 60947-5-6
Current consumption, sensor is activated≤ 1 mA
Current consumption, sensor is not activated≥ 2.2 mA
Cable materialPVC
Conductor size0.5 mm²
Cable diameterØ 5.4 mm
Cable resistance50 Ω
Shock and vibration resistance30 g, 11 ms / 10 … 55 Hz, 1 mm
Ambient operating temperature–20 °C … +70 °C
Housing materialBrass, nickel-plated
Sensing face materialPlastic, PTB
Housing length41 mm
Thread length25 mm
Tightening torque, max.≤ 50 Nm
Weight+ 220 g
Items suppliedMounting nut, brass, nickel-plated (2x)
Type approval certificatePTB 03 ATEX 2037
Ex area category1G, 2G
Input voltage Umax.15 V 2)
Input power Pi max.120 mW 2)
Input current Imax.50 mA 2)
Internal capacitance Ci max.145 nF 2)
Internal inductance Li max.110 µH 2)
Nominal voltage8.2 V DC 3)
Device labelingII 1G Ex ia IIC T6 Ga Ta –20 °C … +70 °C, II 2 G Ex ia IIC T6 Gb Ta: –20 °C … +70 °C
  • 1) When used outside the hazardous area.
  • 2) For connection to a separately certified intrinsically safe circuit only.
  • 3) 1 kΩ.

Safety-related parameters

MTTFD9,926 years
DCavg0 %

Title