inosakiInosakiinosaki

Contact Us
sales@365accountings.com   

KT8L-N3756 Contrast Sensors – SICK Sensor

USD $ 3,249.54

SKU: 1041352

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1041352
Contrast Sensor Model: KT8L-N3756
OEM Spec Ref 

Features

Dimensions (W x H x D)30.4 mm x 53 mm x 80 mm
Sensing distance150 mm 1)
Housing design (light emission)Large
Light sourceLaser, red 2)
Laser classII (EN 60825-1:2014), IEC 60825-1:2014
Wave length655 nm
Light emissionLong side of housing
Light spot sizeØ 3 mm 3)
Light spot directionRound
Operating distance30 mm … 600 mm 4)
AdjustmentTeach-in button
Teach-in mode

Static 2-point teach-in

Dynamic teach-in (min/max)

FunctionAutomatic drift correction
  • 1) From front edge of lens.
  • 2) Average service life: 50,000 h at TU = +25 °C.
  • 3) At focal point = sensing distance 150 mm.
  • 4) With respect to black-white contrast 6 % / 90 %.

 

Mechanics/electronics

Supply voltage10 V DC … 30 V DC 1)
Ripple≤ 5 Vpp 2)
Current consumption< 80 mA 3)
Switching frequency17 kHz 4)
Response time30 µs 5)
Jitter< 15 µs
Switching outputNPN
Switching output (voltage)NPN: HIGH = approx. U/ LOW ≤ 2 V
Analog output0.3 mA … 20 mA
Output current Imax.100 mA
Input, teach-in (ET)

NPN

Teach: U < 2 V

Run: U = 10 V … < UV

Retention time (ET)25 ms, non-volatile memory
Time delay20 ms, adjustable
Connection typeMale connector M12, 5-pin
Protection classII 6)
Circuit protection

UV connections, reverse polarity protected

Output Q short-circuit protected

Interference pulse suppression

Enclosure ratingIP67
Weight400 g
Housing materialMetal, zinc diecast
Optics materialGlass
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) With light/dark ratio 1:1.
  • 5) Signal transit time with resistive load.
  • 6) Reference voltage DC 50 V.

Title