inosakiInosakiinosaki

Contact Us
sales@365accountings.com   

Modicon M221 – IO Relay – Schneider PLC

USD $ 160.65USD $ 315.21

SKU: N/A

Specifications

Main
Part NumberTM221C24RTM221C40R
Range of productModicon M221Modicon M221
Product or component typeLogic controllerLogic controller
[Us] rated supply voltage100…240 V AC100…240 V AC
discrete input number14, discrete input conforming to IEC 61131-2 Type 124, discrete input conforming to IEC 61131-2 Type 1
analogue input number2 at 0…10 V2 at 0…10 V
Discrete output typeRelay normally openRelay normally open
discrete output number10 relay16 relay
discrete output voltage5…125 V DC
5…250 V AC
5…125 V DC
5…250 V AC
discrete output current2:00 AM0.083333333
Complementary
Discrete I/O number2440
maximum number of I/O expansion module7 for transistor output
7 for relay output
7 for relay output
Supply voltage limits85…264 V85…264 V
Network frequency50/60 Hz50/60 Hz
Inrush current40 A40 A
maximum power consumption in VA55 VA at 100…240 V with max number of I/O expansion module
32 VA at 100…240 V without I/O expansion module
67 VA at 100…240 V with max number of I/O expansion module
37 VA at 100…240 V without I/O expansion module
power supply output current0.52 A 5 V for expansion bus
0.16 A 24 V for expansion bus
0.52 A 5 V for expansion bus
0.24 A 24 V for expansion bus
discrete input logicSink or source (positive/negative)Sink or source (positive/negative)
Discrete input voltage24 V24 V
Discrete input voltage typeDCDC
Analogue input resolution10 bits10 bits
LSB value10 mV10 mV
conversion time1 ms per channel + 1 controller cycle time for analogue input analog input1 ms per channel + 1 controller cycle time for analogue input analog input
permitted overload on inputs+/- 30 V DC for 5 min (maximum) for analog input
+/- 13 V DC (permanent) for analog input
+/- 30 V DC for 5 min (maximum) for analog input
+/- 13 V DC (permanent) for analog input
voltage state 1 guaranteed>= 15 V for input>= 15 V for input
voltage state 0 guaranteed<= 5 V for input<= 5 V for input
discrete input current7 mA for discrete input
5 mA for fast input
7 mA for discrete input
5 mA for fast input
input impedance3.4 kOhm for discrete input
100 kOhm for analog input
4.9 kOhm for fast input
3.4 kOhm for discrete input
100 kOhm for analog input
4.9 kOhm for fast input
response time35 µs turn-off, I2…I5 terminal(s) for input
10 ms turn-on for output
10 ms turn-off for output
5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input
35 µs turn-on, other terminals terminal(s) for input
5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input
100 µs turn-off, other terminals terminal(s) for input
35 µs turn-off, I2…I5 terminal(s) for input
10 ms turn-on for output
10 ms turn-off for output
5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input
35 µs turn-on, other terminals terminal(s) for input
5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input
100 µs turn-off, other terminals terminal(s) for input
configurable filtering time0 ms for input
3 ms for input
12 ms for input
0 ms for input
3 ms for input
12 ms for input
output voltage limits125 V DC
277 V AC
125 V DC
277 V AC
maximum current per output common4 A at COM 2
7 A at COM 0
7 A at COM 1
7A
absolute accuracy error+/- 1 % of full scale for analog input+/- 1 % of full scale for analog input
electrical durability100000 cycles AC-12, 120 V, 240 VA, resistive
100000 cycles AC-12, 240 V, 480 VA, resistive
300000 cycles AC-12, 120 V, 80 VA, resistive
300000 cycles AC-12, 240 V, 160 VA, resistive
100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive
100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive
100000 cycles DC-12, 24 V, 48 W, resistive
300000 cycles DC-12, 24 V, 16 W, resistive
100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)
300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
100000 cycles AC-12, 120 V, 240 VA, resistive
100000 cycles AC-12, 240 V, 480 VA, resistive
300000 cycles AC-12, 120 V, 80 VA, resistive
300000 cycles AC-12, 240 V, 160 VA, resistive
100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive
100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive
100000 cycles DC-12, 24 V, 48 W, resistive
300000 cycles DC-12, 24 V, 16 W, resistive
100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)
300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
switching frequency20 switching operations/minute with maximum load20 switching operations/minute with maximum load
mechanical durability20000000 cycles for relay output20000000 cycles for relay output
minimum load1 mA at 5 V DC for relay output1 mA at 5 V DC for relay output
protection typeWithout protection at 5 AWithout protection at 5 A
reset time1 s1 s
memory capacity256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
data backed up256 kB built-in flash memory for backup of application and data256 kB built-in flash memory for backup of application and data
data storage equipment2 GB SD card (optional)2 GB SD card (optional)
battery typeBR2032 lithium non-rechargeable, battery life: 4 year(s)BR2032 lithium non-rechargeable, battery life: 4 year(s)
backup time1 year at 25 °C (by interruption of power supply)1 year at 25 °C (by interruption of power supply)
execution time for 1 KInstruction0.3 ms for event and periodic task0.3 ms for event and periodic task
execution time per instruction0.2 µs Boolean0.2 µs Boolean
exct time for event task60 µs response time60 µs response time
Maximum size of object areas255 %C counters
8000 %MW memory words
512 %M memory bits
512 %KW constant words
255 %TM timers
512 %M memory bits
512 %KW constant words
8000 %MW memory words
255 %C counters
255 %TM timers
Realtime clockWithWith
clock drift<= 30 s/month at 25 °C<= 30 s/month at 25 °C
regulation loopAdjustable PID regulator up to 14 simultaneous loopsAdjustable PID regulator up to 14 simultaneous loops
counting input number4 fast input (HSC mode) at 100 kHz 32 bits4 fast input (HSC mode) at 100 kHz 32 bits
counter functionA/B
Single phase
Pulse/direction
Single phase
Pulse/direction
A/B
integrated connection typeUSB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with RJ45 connector and RS485 interface
Non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface
USB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with RJ45 connector and RS485 interface
Non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface
supply(Serial)serial link supply: 5 V, <200 mA(Serial)serial link supply: 5 V, <200 mA
transmission rate1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
480 Mbit/s for USB
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
480 Mbit/s for USB
communication port protocolUSB port: USB – SoMachine-Network
Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network
USB port: USB – SoMachine-Network
Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network
local signalling1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED (green) for SL1
1 LED (green) for SL2
1 LED per channel (green) for I/O state
1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED (green) for SL1
1 LED (green) for SL2
1 LED per channel (green) for I/O state
electrical connectionRemovable screw terminal block for inputs
removable screw terminal block for outputs
terminal block, 3 terminal(s) for connecting the 24 V DC power supply
connector, 4 terminal(s) for analogue inputs
Mini B USB 2.0 connector for a programming terminal
Removable screw terminal block for inputs
removable screw terminal block for outputs
terminal block, 3 terminal(s) for connecting the 24 V DC power supply
connector, 4 terminal(s) for analogue inputs
Mini B USB 2.0 connector for a programming terminal
maximum cable distance between devicesShielded cable: <10 m for fast input
Unshielded cable: <30 m for output
Unshielded cable: <30 m for digital input
Unshielded cable: <1 m for analog input
Shielded cable: <10 m for fast input
Unshielded cable: <30 m for output
Unshielded cable: <30 m for digital input
Unshielded cable: <1 m for analog input
insulationBetween input and internal logic at 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
Between supply and ground at 1500 V AC
Between sensor power supply and ground at 500 V AC
Between input and ground at 500 V AC
Between output and ground at 1500 V AC
Between supply and internal logic at 2300 V AC
Between sensor power supply and internal logic at 500 V AC
Between output and internal logic at 2300 V AC
Between Ethernet terminal and internal logic at 500 V AC
Between supply and sensor power supply at 2300 V AC
Between input and internal logic at 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
Between supply and ground at 1500 V AC
Between sensor power supply and ground at 500 V AC
Between input and ground at 500 V AC
Between output and ground at 1500 V AC
Between supply and internal logic at 2300 V AC
Between sensor power supply and internal logic at 500 V AC
Between output and internal logic at 2300 V AC
Between Ethernet terminal and internal logic at 500 V AC
Between supply and sensor power supply at 2300 V AC
MarkingCECE
sensor power supply24 V DC at 250 mA supplied by the controller24 V DC at 250 mA supplied by the controller
mounting supportTop hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
Height90 mm90 mm
Depth70 mm70 mm
Width110 mm160 mm
Net weight0.395 kg0.456 kg
Environment
standardsEN/IEC 61010-2-201
EN/IEC 60664-1
EN/IEC 61131-2
EN/IEC 61131-2
EN/IEC 60664-1
EN/IEC 61010-2-201
Product certificationsCSA
LR
ABS
IACS E10
DNV-GL
RCM
cULus
EAC
RCM
IACS E10
LR
CSA
cULus
DNV-GL
ABS
EAC
Environmental characteristicOrdinary and hazardous locationOrdinary and hazardous location
resistance to electrostatic discharge8 kV in air conforming to EN/IEC 61000-4-2
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2
4 kV on contact conforming to EN/IEC 61000-4-2
resistance to electromagnetic fields10 V/m 80 MHz…1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz…2 GHz conforming to EN/IEC 61000-4-3
1 V/m 2…2.7 GHz conforming to EN/IEC 61000-4-3
10 V/m 80 MHz…1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz…2 GHz conforming to EN/IEC 61000-4-3
1 V/m 2…2.7 GHz conforming to EN/IEC 61000-4-3
resistance to magnetic fields30 A/m 50/60 Hz conforming to EN/IEC 61000-4-830 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
resistance to fast transients2 kV (power lines) conforming to EN/IEC 61000-4-4
2 kV (relay output) conforming to EN/IEC 61000-4-4
1 kV (I/O) conforming to EN/IEC 61000-4-4
1 kV (Ethernet line) conforming to EN/IEC 61000-4-4
1 kV (serial link) conforming to EN/IEC 61000-4-4
2 kV (power lines) conforming to EN/IEC 61000-4-4
2 kV (relay output) conforming to EN/IEC 61000-4-4
1 kV (I/O) conforming to EN/IEC 61000-4-4
1 kV (Ethernet line) conforming to EN/IEC 61000-4-4
1 kV (serial link) conforming to EN/IEC 61000-4-4
surge withstand2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5
2 kV relay output common mode conforming to EN/IEC 61000-4-5
1 kV I/O common mode conforming to EN/IEC 61000-4-5
1 kV shielded cable common mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5
1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5
1 kV relay output differential mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5
2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5
2 kV relay output common mode conforming to EN/IEC 61000-4-5
1 kV I/O common mode conforming to EN/IEC 61000-4-5
1 kV shielded cable common mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5
1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5
1 kV relay output differential mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5
resistance to conducted disturbances10 V 0.15…80 MHz conforming to EN/IEC 61000-4-6
3 V 0.1…80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
10 V 0.15…80 MHz conforming to EN/IEC 61000-4-6
3 V 0.1…80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
electromagnetic emissionConducted emissions – test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 120…69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011
Conducted emissions – test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011
Radiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 79…63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011
Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 120…69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011
Conducted emissions – test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011
Radiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 79…63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011
Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to EN/IEC 55011
Immunity to microbreaks10 ms10 ms
ambient air temperature for operation-10…55 °C (horizontal installation)
-10…35 °C (vertical installation)
-10…55 °C (horizontal installation)
-10…35 °C (vertical installation)
Ambient air temperature for storage-25…70 °C-25…70 °C
relative humidity10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
IP degree of protectionIP20 with protective cover in placeIP20 with protective cover in place
Pollution degree<= 2<= 2
Operating altitude0…2000 m0…2000 m
Storage altitude0…3000 m0…3000 m
vibration resistance3.5 mm at 5…8.4 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
1 gn at 8.4…150 Hz on symmetrical rail
1 gn at 8.4…150 Hz on panel mounting
3.5 mm at 5…8.4 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
1 gn at 8.4…150 Hz on symmetrical rail
1 gn at 8.4…150 Hz on panel mounting
shock resistance98 m/s² for 11 ms98 m/s² for 11 ms
Packing Units
Unit Type of Package 1PCEPCE
Number of Units in Package 111
Package 1 Height11.116 cm10.92 cm
Package 1 Width14.219 cm14.48 cm
Package 1 Length15.643 cm21.08 cm
Package 1 Weight640.0 g0.85 kg
Unit Type of Package 2CARCAR
Number of Units in Package 22012
Package 2 Height29.1 cm29.4 cm
Package 2 Width39.5 cm39.5 cm
Package 2 Length56.3 cm55.7 cm
Package 2 Weight13.87 kg11.021 kg

 

WeightN/A
DimensionsN/A