inosakiInosakiinosaki

Contact Us
sales@365accountings.com   

Modicon M340 – Processor Module – Schneider Modules

USD $ 533.61USD $ 1,236.27

SKU: N/A

Specifications

Main
Part NumberBMXP342000BMXP3420102BMXP342020
Range of productModicon M340 automation platformModicon M340 automation platformModicon M340 automation platform
Product or component typeProcessor moduleProcessor moduleProcessor module
Number of racks144
Number of slots111111
discrete I/O processor capacity1024 I/O single-rack configuration1024 I/O multi-rack configuration
704 I/O single-rack configuration
1024 I/O multi-rack configuration
704 I/O single-rack configuration
analogue I/O processor capacity256 I/O multi-rack configuration
66 I/O single-rack configuration
256 I/O multi-rack configuration
66 I/O single-rack configuration
256 I/O multi-rack configuration
66 I/O single-rack configuration
Number of application specific channel363636
monitoringDiagnostic counters Modbus
Event counters Modbus
Diagnostic counters Modbus
Event counters Modbus
Diagnostic counters Modbus
Event counters Modbus
Complementary
Control channelsProgrammable loopsProgrammable loopsProgrammable loops
integrated connection typeNon isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS232C, transmission mode: 2 twisted shielded pairs at 0.3…19.2 kbit/s full duplex
Non isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
Non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS232C, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
Non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
USB port at 12 Mbit/s
Non isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS232C, transmission mode: 2 twisted shielded pairs at 0.3…19.2 kbit/s full duplex
Non isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
Non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS232C, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
Non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
USB port at 12 Mbit/s
CANopen master bus SUB-D 9, transmission mode: 2 twisted shielded pairs at 20 kbit/s…1 Mbit/s
Non isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS232C, transmission mode: 2 twisted shielded pairs at 0.3…19.2 kbit/s full duplex
Non isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
Non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS232C, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
Non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
USB port at 12 Mbit/s
Ethernet TCP/IP RJ45, transmission mode: 1 twisted pair at 10/100 Mbit/s
communication module processor capacity2 Ethernet communication module
4 AS-Interface module
2 Ethernet communication module
4 AS-Interface module
2 Ethernet communication module
4 AS-Interface module
number of devices per segment0…32 (character mode)
0…32 (Modbus)
0…32 (character mode)
0…32 (Modbus)
0…16 for <205 m (CANopen)
0…32 for <185 m (CANopen)
0…64 for <160 m (CANopen)
0…32 (character mode)
0…32 (Modbus)
number of devices2 point-to-point character mode
2 point-to-point Modbus
2 point-to-point character mode
2 point-to-point Modbus
2 point-to-point character mode
2 point-to-point Modbus
bus length0…10 m serial link non isolated character mode segment
0…10 m serial link non isolated Modbus segment
0…1000 m serial link isolated character mode segment
0…1000 m serial link isolated Modbus segment
0…15 m character mode point-to-point
0…15 m Modbus point-to-point
0…10 m serial link non isolated character mode segment
0…10 m serial link non isolated Modbus segment
0…1000 m serial link isolated character mode segment
0…1000 m serial link isolated Modbus segment
0…15 m character mode point-to-point
0…15 m Modbus point-to-point
0…10 m serial link non isolated character mode segment
0…10 m serial link non isolated Modbus segment
0…1000 m serial link isolated character mode segment
0…1000 m serial link isolated Modbus segment
0…15 m character mode point-to-point
0…15 m Modbus point-to-point
maximum tap links length<15 m serial link non isolated character mode segment
<15 m serial link non isolated Modbus segment
<40 m serial link isolated character mode segment
<40 m serial link isolated Modbus segment
<15 m serial link non isolated character mode segment
<15 m serial link non isolated Modbus segment
<40 m serial link isolated character mode segment
<40 m serial link isolated Modbus segment
<15 m serial link non isolated character mode segment
<15 m serial link non isolated Modbus segment
<40 m serial link isolated character mode segment
<40 m serial link isolated Modbus segment
number of addresses0…248 for character mode
0…248 for Modbus
0…248 for character mode
0…248 for Modbus
0…248 for character mode
0…248 for Modbus
requests1 K data bytes per request character mode
252 data bytes per RTU request Modbus
504 data bytes per ASCII request Modbus
1 K data bytes per request character mode
252 data bytes per RTU request Modbus
504 data bytes per ASCII request Modbus
1 K data bytes per request character mode
252 data bytes per RTU request Modbus
504 data bytes per ASCII request Modbus
control parameterOne CRC on each frame (RTU) Modbus
One LRC on each frame (ASCII) character mode
One LRC on each frame (ASCII) Modbus
One CRC on each frame (RTU) Modbus
One LRC on each frame (ASCII) character mode
One LRC on each frame (ASCII) Modbus
One CRC on each frame (RTU) Modbus
One LRC on each frame (ASCII) character mode
One LRC on each frame (ASCII) Modbus
memory descriptionInternal RAM 4096 kB
Internal RAM 256 kB data
Internal RAM 3584 kB program constants and symbols
Supplied memory card (BMXRMS008MP) backup of programs, constants, symbols and data
Supplied memory card (BMXRMS008MP) backup of programs, constants, symbols and data
Internal RAM 4096 kB
Internal RAM 256 kB data
Internal RAM 3584 kB program constants and symbols
Supplied memory card (BMXRMS008MP) backup of programs, constants, symbols and data
Internal RAM 4096 kB
Internal RAM 256 kB data
Internal RAM 3584 kB program constants and symbols
Supplied memory card (BMXRMS008MP) activation of standard web server, class B10
maximum size of object areas128 kB unlocated internal data
16250 %Mi located internal bits
32464 %MWi internal words located internal data
32760 %KWi constant words located internal data
256 kB unlocated internal data
32634 %Mi located internal bits
256 kB unlocated internal data
32634 %Mi located internal bits
default size of object areas128 %KWi constant words located internal data
256 %Mi located internal bits
512 %MWi internal words located internal data
1024 %MWi internal words located internal data
256 %KWi constant words located internal data
512 %Mi located internal bits
1024 %MWi internal words located internal data
256 %KWi constant words located internal data
512 %Mi located internal bits
Application structure1 cyclic/periodic master task
1 periodic fast task
No auxiliary task
32 event tasks
No auxiliary task
1 cyclic/periodic master task
1 periodic fast task
64 event tasks
1 cyclic/periodic master task
1 periodic fast task
No auxiliary task
64 event tasks
execution time per instruction0.18 µs Boolean
0.26 µs double-length words
0.38 µs single-length words
1.74 µs floating points
0.12 µs Boolean
0.17 µs double-length words
0.25 µs single-length words
1.16 µs floating points
0.12 µs Boolean
0.17 µs double-length words
0.25 µs single-length words
1.16 µs floating points
number of instructions per ms4.2 Kinst/ms 65 % Boolean + 35 % fixed arithmetic
5.4 Kinst/ms 100 % Boolean
6.4 Kinst/ms 65 % Boolean + 35 % fixed arithmetic
8.1 Kinst/ms 100 % Boolean
6.4 Kinst/ms 65 % Boolean + 35 % fixed arithmetic
8.1 Kinst/ms 100 % Boolean
system overhead0.2 ms for fast task
1.05 ms for master task
0.13 ms for fast task
0.7 ms for master task
0.13 ms for fast task
0.7 ms for master task
current consumption72 mA at 24 V DC90 mA at 24 V DC95 mA at 24 V DC
SupplyInternal power supply via rackInternal power supply via rackInternal power supply via rack
MarkingCECECE
status LED1 LED (green) processor running (RUN)
1 LED (red) I/O module fault (I/O)
1 LED (red) memory card fault (CARD ERR)
1 LED (red) processor or system fault (ERR)
1 LED (yellow) activity on Modbus (SER COM)
1 LED (green) integrated machine/installation bus operational (CAN RUN)
1 LED (green) processor running (RUN)
1 LED (red) I/O module fault (I/O)
1 LED (red) integrated machine/installation bus fault (CAN ERR)
1 LED (red) memory card fault (CARD ERR)
1 LED (red) processor or system fault (ERR)
1 LED (yellow) activity on Modbus (SER COM)
1 LED (green) activity on Ethernet network (ETH ACT)
1 LED (green) processor running (RUN)
1 LED (green) status of Ethernet network (ETH STS)
1 LED (red) data rate (ETH 100)
1 LED (red) I/O module fault (I/O)
1 LED (red) memory card fault (CARD ERR)
1 LED (red) processor or system fault (ERR)
1 LED (yellow) activity on Modbus (SER COM)
Net weight0.2 kg0.21 kg0.205 kg
Environment
Ambient air temperature for operation0…60 °C0…60 °C0…60 °C
relative humidity10…95 % without condensation10…95 % without condensation10…95 % without condensation
IP degree of protectionIP20IP20IP20
Protective treatmentTCTCTC
Directives2014/35/EU – low voltage directive
2014/30/EU – electromagnetic compatibility
2014/35/EU – low voltage directive
2014/30/EU – electromagnetic compatibility
2014/35/EU – low voltage directive
2014/30/EU – electromagnetic compatibility
product certificationsCE
UL
CSA
RCM
EAC
Merchant Navy
CE
UL
CSA
RCM
EAC
Merchant Navy
CE
UL
CSA
RCM
EAC
Merchant Navy
standardsEN 61131-2
EN/IEC 61010-2-201
UL 61010-2-201
CSA C22.2 No 61010-2-201
IACS E10
EN/IEC 61000-6-5, interface type 1 and type 2
EN/IEC 61850-3, location G
EN 61131-2
EN/IEC 61010-2-201
UL 61010-2-201
CSA C22.2 No 61010-2-201
IACS E10
EN/IEC 61000-6-5, interface type 1 and type 2
EN/IEC 61850-3, location G
EN 61131-2
EN/IEC 61010-2-201
UL 61010-2-201
CSA C22.2 No 61010-2-201
IACS E10
EN/IEC 61000-6-5, interface type 1 and type 2
EN/IEC 61850-3, location G
environmental characteristicHazardous location class I division 2Hazardous location class I division 2Hazardous location class I division 2
Packing Units
Unit Type of Package 1PCEPCEPCE
Number of Units in Package 1111
Package 1 Height5.5 cm5.5 cm5.5 cm
Package 1 Width11.0 cm11.0 cm11.0 cm
Package 1 Length11.5 cm11.6 cm11.5 cm
Package 1 Weight240.0 g250.0 g248.0 g
Unit Type of Package 2S02S02S02
Number of Units in Package 2151515
Package 2 Height15.0 cm15.0 cm15.0 cm
Package 2 Width30.0 cm30.0 cm30.0 cm
Package 2 Length40.0 cm40.0 cm40.0 cm
Package 2 Weight3.915 kg4.0 kg3.98 kg
Contractual warranty
Warranty18 months18 months18 months
WeightN/A
DimensionsN/A

Title