inosakiInosakiinosaki

Contact Us
sales@365accountings.com   

Modicon TM3 – Input/Output Analog Module – Schneider Modules

USD $ 149.73

SKU: N/A

Specifications

Main
Part Number

TM3AM6

TM3TM3
Range of productModicon TM3Modicon TM3
Product or component typeInput/output analog moduleInput/output analog module
Range compatibilityModicon M221Modicon M221
Modicon M241Modicon M241
Modicon M251Modicon M251
Modicon M262Modicon M262
Analogue input number42
analogue input typeCurrent 4…20 mACurrent 4…20 mA
current 0…20 mAcurrent 0…20 mA
voltage 0…10 Vvoltage 0…10 V
voltage – 10…10 Vvoltage – 10…10 V
thermocouple – 200…1000 °C with thermocouple J
thermocouple – 200…1300 °C with thermocouple K
thermocouple 0…1760 °C with thermocouple R
thermocouple 0…1760 °C with thermocouple S
thermocouple 0…1820 °C with thermocouple B
thermocouple – 200…400 °C with thermocouple T
thermocouple – 200…1300 °C with thermocouple N
thermocouple – 200…800 °C with thermocouple E
thermocouple 0…2315 °C with thermocouple C
Ni 100/Ni 1000 temperature probe – 60…180 °C
Pt 100 temperature probe – 200…850 °C
Pt 1000 temperature probe – 200…600 °C
Analogue output number21
analogue output typeCurrent: 4…20 mACurrent: 4…20 mA
Current: 0…20 mACurrent: 0…20 mA
Voltage: 0…10 VVoltage: 0…10 V
Voltage: – 10…10 VVoltage: – 10…10 V
Complementary
analogue input resolution12 bits16 bits
11 bits + sign15 bits + sign
permissible continuous overload13 V, analogue input type: voltage13 V, analogue input type: voltage
40 mA, analogue input type: current40 mA, analogue input type: current
input impedance<= 50 Ohm current<= 50 Ohm current
>= 1 MOhm voltage>= 1 MOhm voltage
>= 1 MOhm thermocouple
>= 1 MOhm temperature probe
Analogue output resolution12 bits12 bits
11 bits + sign
LSB value2.44 mV 0…10 Vvoltage0.15 mV 0…10 Vvoltage
4.88 mV – 10…10 Vvoltage0.30 mV – 10…10 Vvoltage
4.88 µA 0…20 mAcurrent0.30 µA 0…20 mAcurrent
3.91 µA 4…20 mAcurrent0.244 µA 4…20 mAcurrent
0.1 °Ctemperature probe
0.1 °Cthermocouple
2.44 mV 0…10 V voltage
4.88 mV – 10…10 V voltage
4.88 µA 0…20 mA current
3.91 µA 4…20 mA current
Load typeResistiveResistive
load impedance ohmic1 kOhm voltage1 kOhm voltage
300 Ohm current300 Ohm current
Stabilisation time1 ms1 ms
conversion time1 ms + 1 ms per channel + 1 controller cycle time100 ms + 100 ms per channel + 1 controller cycle time for analogue input thermocouple
100 ms + 100 ms per channel + 1 controller cycle time for analogue input temperature probe
10 ms + 10 ms per channel + 1 controller cycle time for analogue input voltage/current
sampling duration1 ms10 ms, analogue input type: voltage/current
10 ms100 ms, analogue input type: voltage/current
100 ms, analogue input type: thermocouple
100 ms, analogue input type: temperature probe
absolute accuracy error+/- 1 % of full scale+/- 6 °C at 25 °C for thermocouple R, S 0…200 °C
+/- 0.2 % of full scale at 25 °C+/- 0.4 % of full scale at 25 °C for thermocouple K – 200…0 °C
Temperature drift+/- 0.01 %FS/°C+/- 0.4 % of full scale at 25 °C for thermocouple J – 200…0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple E – 200…0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple T – 200…0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple N – 200…0 °C
+/- 0.1 % of full scale at 25 °C for analogue input voltage/current
+/- 0.1 % of full scale at 25 °C for thermocouple C 0…2315 °C
+/- 0.1 % of full scale at 25 °C for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe
+/- 0.1 % of full scale at 25 °C for thermocouple R, S 200…1760 °C
+/- 0.1 % of full scale at 25 °C for thermocouple B 300…1820 °C
+/- 0.1 % of full scale at 25 °C for thermocouple K 0…1300 °C
+/- 0.1 % of full scale at 25 °C for thermocouple J 0…1000 °C
+/- 0.1 % of full scale at 25 °C for thermocouple E 0…800 °C
+/- 0.1 % of full scale at 25 °C for thermocouple T 0…400 °C
+/- 0.1 % of full scale at 25 °C for thermocouple N 0…1300 °C
+/- 0.1 % of full scale at 25 °C for analogue output voltage/current
+/- 0.006 %FS/°C
repeat accuracy+/-0.5 %FS for input+/-0.5 %FS for input
+/-0.5 %FS for output+/- 0.4 %FS for output
non-linearity+/- 0.2 %FS+/- 0.01 %FS, analogue output type: analog output
+/- 0.1 %FS, analogue input type: analog input
Output ripple20 mV20 mV
Cross talk<= 1 LSB<= 1 LSB
[Us] rated supply voltage24 V DC24 V DC
Supply voltage limits20.4…28.8 V20.4…28.8 V
type of cableTwisted shielded pairs cable <30 m for input/output circuitTwisted shielded pairs cable <30 m for input/output circuit
current consumption45 mA at 5 V DC via bus connector no load55 mA at 24 V DC via external supply no load
55 mA at 5 V DC via bus connector full load55 mA at 5 V DC via bus connector no load
55 mA at 24 V DC via external supply no load60 mA at 5 V DC via bus connector full load
100 mA at 24 V DC via external supply full load80 mA at 24 V DC via external supply full load
local signalling1 LED (green) for PWR1 LED (green) for PWR
electrical connection10 x 1.5 mm² removable screw terminal block with pitch 3.81 mm adjustment for inputs11 x 2.5 mm² removable screw terminal block with pitch 5.08 mm adjustment for inputs, outputs and supply
10 x 1.5 mm² removable screw terminal block with pitch 3.81 mm adjustment for inputs, outputs and supply
insulationBetween input and supply at 1500 V ACBetween input and supply at 1500 V AC
Between input and internal logic at 500 V ACBetween input and internal logic at 500 V AC
Between output and supply at 1500 V ACBetween output and supply at 1500 V AC
Between output and internal logic at 500 V ACBetween output and internal logic at 500 V AC
MarkingCECE
surge withstand1 kV power supply common mode conforming to EN/IEC 61000-4-51 kV power supply common mode conforming to EN/IEC 61000-4-5
0.5 kV power supply differential mode conforming to EN/IEC 61000-4-50.5 kV power supply differential mode conforming to EN/IEC 61000-4-5
1 kV I/O common mode conforming to EN/IEC 61000-4-51 kV I/O common mode conforming to EN/IEC 61000-4-5
0.5 kV I/O differential mode conforming to EN/IEC 61000-4-50.5 kV I/O differential mode conforming to EN/IEC 61000-4-5
mounting supportTop hat type TH35-15 rail conforming to IEC 60715Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kitplate or panel with fixing kit
Height90 mm90 mm
Depth70 mm70 mm
Width23.6 mm23.6 mm
Net weight0.11 kg0.115 kg
Environment
StandardsEN/IEC 61010-2-201EN/IEC 61010-2-201
EN/IEC 61131-2EN/IEC 61131-2
resistance to electrostatic discharge8 kV in air conforming to EN/IEC 61000-4-28 kV in air conforming to EN/IEC 61000-4-2
4 kV on contact conforming to EN/IEC 61000-4-24 kV on contact conforming to EN/IEC 61000-4-2
resistance to electromagnetic fields10 V/m 80 MHz…1 GHz conforming to EN/IEC 61000-4-310 V/m 80 MHz…1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz…2 GHz conforming to EN/IEC 61000-4-33 V/m 1.4 GHz…2 GHz conforming to EN/IEC 61000-4-3
1 V/m 2 GHz…3 GHz conforming to EN/IEC 61000-4-31 V/m 2 GHz…3 GHz conforming to EN/IEC 61000-4-3
resistance to magnetic fields30 A/m conforming to EN/IEC 61000-4-830 A/m conforming to EN/IEC 61000-4-8
resistance to fast transients1 kV (I/O) conforming to EN/IEC 61000-4-41 kV (I/O) conforming to EN/IEC 61000-4-4
resistance to conducted disturbances10 V 0.15…80 MHz conforming to EN/IEC 61000-4-610 V 0.15…80 MHz conforming to EN/IEC 61000-4-6
3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
electromagnetic emissionRadiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011Radiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011
Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 230…1000 MHz conforming to EN/IEC 55011Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 230…1000 MHz conforming to EN/IEC 55011
Immunity to microbreaks10 ms10 ms
ambient air temperature for operation-10…55 °C horizontal installation-10…55 °C horizontal installation
-10…35 °C vertical installation-10…35 °C vertical installation
Ambient air temperature for storage-25…70 °C-25…70 °C
relative humidity10…95 %, without condensation (in operation)10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)10…95 %, without condensation (in storage)
IP degree of protectionIP20IP20
Pollution degree22
Operating altitude0…2000 m0…2000 m
Storage altitude0…3000 m0…3000 m
vibration resistance3.5 mm at 5…8.4 Hz on DIN rail3.5 mm at 5…8.4 Hz on DIN rail
3 gn at 8.4…150 Hz on DIN rail3 gn at 8.4…150 Hz on DIN rail
shock resistance15 gn for 11 ms15 gn for 11 ms
Packing Units
Unit Type of Package 1PCEPCE
Number of Units in Package 111
Package 1 Height10.5 cm7.611 cm
Package 1 Width12.5 cm10.688 cm
Package 1 Length7.5 cm12.753 cm
Package 1 Weight211.0 g220.0 g
Unit Type of Package 2S04S04
Number of Units in Package 24242
Package 2 Height30.0 cm30.0 cm
Package 2 Width40.0 cm40.0 cm
Package 2 Length60.0 cm60.0 cm
Package 2 Weight9.502 kg10.421 kg

 

WeightN/A
DimensionsN/A

Title