inosakiInosakiinosaki

Contact Us
sales@365accountings.com   

OD1-B035H15U25 Displacement Measurement Sensors – SICK Sensor

USD $ 11,922.96

SKU: 6050506

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6050506
Distance Sensor Model: OD1-B035H15U25
OEM Spec Ref 

Mechanics/electronics

Supply voltage VsDC 12 V (–5 %) … DC 24 V (+10 %)
Power consumption≤ 1.92 W 1)
Warm-up time≤ 5 min
Housing materialStainless steel
Window materialPlastic (PPSU)
Connection typeCable with male connector, M12, 5-pin, 30 cm
Indication4-digit 7-segment display (plus 4 LEDs for status display)
Control elements4 buttons
Weight70 g
Dimensions (W x H x D)17.8 mm x 44.4 mm x 31 mm
Enclosure ratingIP67
Protection classIII
  • 1) Without load, with current output.

 

Performance

Measuring range20 mm … 50 mm
TargetNatural objects
Repeatability6 µm 1) 2)
Linearity± 30 µm 3)
Response time≥ 2 ms 4)
Measuring frequency≤ 2 kHz
Output time≥ 0.5 ms
Light sourceLaser, red
visible red light
Laser class1 (IEC 60825-1:2014, EN 60825-1:2014) 5)
Typ. light spot size (distance)800 µm x 450 µm (35 mm)
Additional functionAveraging 1 … 512x, automatic or manual sensitivity adjustment, Analog outputs can be taught in, digital outputs can be taught in, invertable digital output, switching mode: window (Wnd), switching mode: distance to object (DtO), switiching mode: object between sensor and background (ObSB), multifunctional input: laser-off / external teach-in / trigger
  • 1) Averaging function set to: 512.
  • 2) Constant ambient conditions.
  • 3) Measurement on 90 % remission (ceramic, white).
  • 4) With fixed sensitivity adjustment and averaging setting = 1. With automatic sensitivity and measuring rate 500 µs: 2 … 7.5 ms response time/measuring rate 1,000 µs: 4 … 15 ms response time.
  • 5) Wavelength: 655 nm, max. output: 390 µW (laser class 1) / < 1 mW (laser class 2).

 

Interfaces

Digital output
Number1
TypePNP/NPN, selectable
Analog output
Number1
TypeVoltage output
Voltage0 V … 10 V, > 10,000 Ω
Resolution13.4 bit
Multifunctional input (MF)1 x 1)
  • 1) MF can be used as laser-off, trigger, external teach-in or deactivated.

 

Ambient data

Ambient temperature, operation–10 °C … +50 °C
Ambient temperature, storage–20 °C … +60 °C
Min. rel. humidity (not condensing)35 %
Max. rel. humidity (not condensing)95 %
Temperature drift± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor)
Typ. Ambient light immunityArtificial light: ≤ 3,000 lx

Sunlight: ≤ 10,000 lx

Vibration resistance10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each)
Shock resistance50 G (x, y, z axis 3 times each)