inosakiInosakiinosaki

Contact Us
sales@365accountings.com   

PRO2-P100B25A1 Displacement Measurement Sensors – SICK Sensor

USD $ 18,006.03

SKU: 6052873

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6052873
Distance Sensor Model: PRO2-P100B25A1
OEM Spec Ref 

Mechanics/electronics

Supply voltage VsDC 12 V (–5 %) … DC 24 V (+10 %) 1)
Power consumption≤ 180 mA
Warm-up time≤ 30 min
Housing materialMetal (zinc diecast)
Window materialPlastic (Polycarbonat (PC))
Connection typeFemale connector, HRS, 12-pin (I/O, power supply)
Indication2 LEDs (operational status, Laser on/off)

Dot matrix display

Weight300 g
Dimensions (W x H x D)40 mm x 94.5 mm x 60 mm
Enclosure ratingIP67
Protection classIII
  • 1) When using analog voltage output reduced to 18 V DC (–5%) … 24 V DC (+10%).

Performance

Measuring range75 mm … 125 mm
Measuring width (at measuring distance)17 mm (75 mm)

22 mm (100 mm)

27 mm (125 mm)

TargetNatural objects
Repeatability25 µm, x-direction 1) 2)

2 µm, z-direction

LinearityX-direction ± 170 µm … ± 270 µm 3) 4)

Z-direction ± 50 µm

Response time≥ 5 ms 5)
Light sourceLaser, red
visible red light
Laser class2, complies with 21 CFR 1040.10 and 1040.11 except for the conformance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1:2014, EN 60825-1:2014) 6)
Typ. light spot size (distance)0.3 mm x 32 mm
Additional functionTimer (ON-OFF delay, one shot, off), averaging 1 … 1,023, sensitivity (adjustable), Measurement functions (average, peak height, bottom height, width, peak height position, bottom height position, edge position, edge count, tilt, area, length, diameter)
  • 1) Typical value; actual value depends on settings and environmental conditions. For details see field of view.
  • 2) Measurement on 90 % remission (ceramic, white), for OD25-x measurement on mirror; averaging set to: 256; constant ambient conditions.
  • 3) Measurement on 90 % remission (ceramic, white).
  • 4) Constant ambient conditions.
  • 5) Typical value, high-res mode.
  • 6) Wavelength: 655 nm, max. output: 1 mW.

Interfaces

Serial✔ , RS-485
Data transmission rate9.6 kbit/s … 4 Mbit/s, half-duplex
Digital output
Number3
TypePNP
Maximum output current IA≤ 100 mA
Analog output
Number1
TypeCurrent output
Current4 mA … 20 mA, ≤ 300 Ω 1)
External inputSelectable from bank, trigger, hold, reset, laser off and offset
  • 1) 24 mA for measuring out of range.

Ambient data

Ambient temperature, operation–10 °C … +40 °C, Operating temperature at VS = 24 V
Ambient temperature, storage–20 °C … +60 °C
Max. rel. humidity (not condensing)85 %
Temperature drift± 0.05 % FS/K (FS = Full Scale = Measuring range of sensor)
Typ. Ambient light immunityArtificial light: ≤ 3,000 lx

Sunlight: ≤ 10,000 lx

Vibration resistance10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each)
Shock resistance50 G (x, y, z axis 3 times each)

 

Related products

Title