QUINT-PS/1AC/48DC/20 – 2866695 – Phoenix Contact Power Supply

USD $ 636.30

SKU: 2866695

Inosaki is one of the largest Phoenix Contact Distributors to provide terminal block, interface module, power supply and relay. And our best offer for terminal block types are Feed-through, Fuse Modular, Spring Cage, Double Level, and Multi-level, hence the series model references to  PT Series, ST Series, TB Series, UT Series, UK Series. In additional for power supply are QUINT Power, STEP Power, Trio Power, and UNO Power. Please email us for catalog: sales@365accountings.com

Product Description

QUINT POWER power supplies with maximum functionality
QUINT POWER circuit breakers magnetically and therefore quickly trip at six times the nominal current, for selective and therefore cost-effective system protection. The high level of system availability is additionally ensured, thanks to preventive function monitoring, as it reports critical operating states before errors occur.
Reliable starting of heavy loads takes place via the static power reserve POWER BOOST. Thanks to the adjustable voltage, all ranges between 5 V DC … 56 V DC are covered.

Dimensions

Article Number2866695
Width180 mm
Height130 mm
Depth125 mm
Width with alternative assembly122 mm
Height with alternative assembly130 mm
Depth with alternative assembly183 mm
Installation distance right/left5 mm / 5 mm
Installation distance top/bottom50 mm / 50 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C … 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (start-up type tested)-40 °C
Ambient temperature (storage/transport)-40 °C … 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2
Installation height6000 m

Input data

Nominal input voltage range100 V AC … 240 V AC
120 V DC … 300 V DC (UL 508: ≤ 250 V DC)
Input voltage range85 V AC … 264 V AC
90 V DC … 300 V DC (UL 508: ≤ 250 V DC)
Dielectric strength maximum300 V AC
AC frequency range45 Hz … 65 Hz
Frequency range DC0 Hz
Discharge current to PE< 3.5 mA
Current consumption8.7 A (120 V AC)
4.5 A (230 V AC)
9.4 A (110 V DC)
4.6 A (220 V DC)
Nominal power consumption1046 VA
Inrush current< 15 A (typical)
Mains buffering timetyp. 20 ms (120 V AC)
typ. 22 ms (230 V AC)
Input fuse20 A (fast blow, internal)
Recommended breaker for input protection6 A … 16 A (AC: Characteristics B, C, D, K)
Type of protectionTransient surge protection
Protective circuit/componentVaristor

Output data

Nominal output voltage48 V DC ±1 %
Setting range of the output voltage (USet)30 V DC … 56 V DC (> 48 V DC, constant capacity restricted)
Nominal output current (IN)20 A (-25 °C … 60 °C, UOUT = 48 V DC)
POWER BOOST (IBoost)22.5 A (-25 °C … 40 °C permanent, UOUT = 48 V DC )
Selective Fuse Breaking (ISFB)100 A (12 ms)
Derating60 °C … 70 °C (2.5%/K)
Connection in parallelyes, for redundancy and increased capacity
Connection in seriesyes
Feedback voltage resistancemax. 60 V DC
Protection against overvoltage at the output (OVP)< 60 V DC
Active current limitationApprox. IBOOST = 22.5 A (for short-circuit)
Control deviation< 1 % (change in load, static 10 % … 90 %)
< 3 % (change in load, dynamic 10 % … 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple< 50 mVPP (with nominal values)
Output power960 W
Typical response time< 0.65 s
Maximum power dissipation in no-load condition12 W
Power loss nominal load max.74 W

General

Net weight3.3 kg
Efficiency> 93 % (for 230 V AC and nominal values)
MTBF (IEC 61709, SN 29500)> 880000 h (25 °C)
> 523000 h (40 °C)
Insulation voltage input/output4 kV AC (type test)
2 kV AC (routine test)
Insulation voltage input / PE3.5 kV AC (type test)
2 kV AC (routine test)
Insulation voltage output / PE500 V DC (routine test)
Degree of protectionIP20
Protection classI
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom

Connection data, input

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.6 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.14
Conductor cross section AWG max.10
Stripping length7 mm
Screw threadM3

Connection data, output

Connection methodScrew connection
Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.16 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.16 mm²
Conductor cross section AWG min.8
Conductor cross section AWG max.6
Stripping length10 mm
Screw threadM3

Connection data for signaling

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.6 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.10
Screw threadM3

Standards

EMC requirements for noise immunityEN 61000-6-1
EN 61000-6-2
EMC requirements for noise emissionEN 61000-6-3
EN 61000-6-4
Standard – Electrical safetyIEC 61010-2-201 (SELV)
Standard – safety for equipment for measurement, control, and laboratory useIEC 61010-1
Standard – Safety extra-low voltageIEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Standard – Safe isolationIEC 61010-2-201
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard – Equipment safetyBG (design tested)
Rail applicationsEN 50121-4
EN 50121-3-2
Overvoltage category EN 62477-1III

Conformance/approvals

UL approvalsUL Listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
CSACAN/CSA-C22.2 No. 60950-1-07
CSA-C22.2 No. 107.1-01
SIQBG (type approved)
Shipbuilding approvalDNV GL (EMC A)

EMC data

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Electrostatic dischargeEN 61000-4-2
Contact discharge8 kV (Test Level 4)
Discharge in air15 kV (Test Level 4)
Electromagnetic HF fieldEN 61000-4-3
Frequency range80 MHz … 1 GHz
Test field strength20 V/m (Test Level 3)
Frequency range1 GHz … 2 GHz
Test field strength10 V/m (Test Level 3)
Frequency range2 GHz … 3 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A
Fast transients (burst)EN 61000-4-4
Input4 kV (Test Level 4 – asymmetrical)
Output2 kV (Test Level 3 – asymmetrical)
Signal2 kV (Test Level 4 – asymmetrical)
CommentsCriterion A
Surge voltage load (surge)EN 61000-4-5
Input2 kV (Test Level 3 – symmetrical)
4 kV (Test Level 4 – asymmetrical)
Output1 kV (Test Level 2 – symmetrical)
2 kV (Test Level 3 – asymmetrical)
Signal1 kV (Test Level 2 – asymmetrical)
CommentsCriterion A
Conducted interferenceEN 61000-4-6
I/O/Sasymmetrical
Frequency range0.15 MHz … 80 MHz
Voltage10 V (Test Level 3)
CommentsCriterion A
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration”
Weight4 kg
Dimensions12.5 × 18 × 13 cm