inosakiInosakiinosaki

Contact Us
sales@365accountings.com   

QUINT4-PS/1AC/12DC/2.5/PT – 2904605 – Phoenix Contact Power Supply

USD $ 163.80

SKU: 2904605

Inosaki is one of the largest Phoenix Contact Distributors to provide terminal block, interface module, power supply and relay. And our best offer for terminal block types are Feed-through, Fuse Modular, Spring Cage, Double Level, and Multi-level, hence the series model references to  PT Series, ST Series, TB Series, UT Series, UK Series. In additional for power supply are QUINT Power, STEP Power, Trio Power, and UNO Power. Please email us for catalog: sales@365accountings.com

Dimensions

Article Number2904605
Width22.5 mm
Height106 mm
Depth90 mm
Installation distance right/left (active, passive)0 mm / 0 mm (POut ≤50 %)
Installation distance right/left (passive)5 mm / 5 mm (POut ≥50% )
Installation distance right/left (active)15 mm / 15 mm (POut ≥50% )
Installation distance top/bottom (active, passive)30 mm / 30 mm (POut ≤50 %)
Installation distance top/bottom (passive)30 mm / 30 mm (POut ≥50% )
Installation distance top/bottom (active)30 mm / 30 mm (POut ≥50% )

Ambient conditions

Degree of protectionIP20
Inflammability class in acc. with UL 94 (housing / terminal blocks)V0
Ambient temperature (operation)-25 °C … 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)-40 °C … 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2
Installation height≤ 5000 m (> 2000 m, observe derating)

Input data

Input voltage range100 V AC … 240 V AC -15 % … +10 %
110 V DC … 250 V DC -20 % … +40 %
Dielectric strength maximum300 V AC 60 s
Frequency range (fN)50 Hz … 60 Hz -10 % … +10 %
Discharge current to PE< 0.25 mA (264 V AC, 60 Hz)
Current consumption0.44 A (100 V AC)
0.35 A (120 V AC)
0.19 A (230 V AC)
0.2 A (240 V AC)
Nominal power consumption32.8 VA
Inrush currenttyp. 11.3 A (at 25 °C)
Mains buffering timetyp. 54 ms (120 V AC)
typ. 54 ms (230 V AC)
Input fuse3.15 A (slow-blow, internal)
Recommended breaker for input protection6 A … 16 A (Characteristic B, C or comparable)
Type of protectionTransient surge protection
Protective circuit/componentVaristor

Output data

Nominal output voltage12 V DC
Setting range of the output voltage (USet)12 V DC … 15 V DC (constant capacity)
Nominal output current (IN)2.5 A
Static Boost (IStat.Boost)3.125 A (≤ 40 °C)
Dynamic Boost (IDyn.Boost)4.5 A (≤ 60 °C (5 s))
Connection in parallelyes, for redundancy and increased capacity
Connection in seriesyes
Feedback voltage resistance≤ 25 V DC
Protection against overvoltage at the output (OVP)≤ 18 V DC
Control deviation< 0.2 % (Static load change 10 % … 90 %)
< 2 % (Dynamic load change 10 % … 90 %, (10 Hz))
< 0.1 % (change in input voltage ±10 %)
Residual ripple< 30 mVPP (with nominal values)
Output power30 W
Typical response time500 ms
Maximum power dissipation in no-load condition< 0.4 W (230 V AC)
< 0.5 W (120 V AC)
Power loss nominal load max.< 3.5 W (120 V AC)
< 3 W (230 V AC)

General

Net weight0.181 kg
Efficiencytyp. 89.5 % (120 V AC)
typ. 90.9 % (230 V AC)
MTBF (IEC 61709, SN 29500)> 1848000 h (25 °C)
> 1060000 h (40 °C)
> 459000 h (60 °C)
Insulation voltage input/output4 kV AC (type test)
3 kV AC (routine test)
Degree of protectionIP20
Protection classII
Inflammability class in acc. with UL 94 (housing / terminal blocks)V0

Connection data, input

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length10 mm

Connection data, output

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length10 mm

Connection data for signaling

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length10 mm

Standards

EMC requirements, power plantIEC 61850-3
EN 61000-6-5
Standard – Safety of transformersEN 61558-2-16
Standard – safety for equipment for measurement, control, and laboratory useIEC 61010-1
Standard – Safety extra-low voltageIEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Standard – Safe isolationIEC 61558-2-16
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Overvoltage category EN 61010-1II (≤ 5000 m)
Overvoltage category EN 62477-1III (≤ 2000 m)

Conformance/approvals

UL approvalsUL Listed UL 61010-1
UL Listed UL 61010-2-201
UL 1310 Class 2 Power Units
ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
SIQCB-Scheme (IEC 61010-1, IEC 61010-2-201)

EMC data

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Conducted noise emissionEN 55016
EN 61000-6-3 (Class B)
Noise emissionEN 55016
EN 61000-6-3 (Class B)
Harmonic currentsEN 61000-3-2
EN 61000-3-2 (Class A)
FlickerEN 61000-3-3
Electrostatic dischargeEN 61000-4-2
Contact discharge8 kV (Test Level 4)
Discharge in air15 kV (Test Level 4)
Electromagnetic HF fieldEN 61000-4-3
Frequency range80 MHz … 1 GHz
Test field strength20 V/m (Test Level X)
Frequency range1 GHz … 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A
Fast transients (burst)EN 61000-4-4
Input4 kV (Test Level 4 – asymmetrical)
Output4 kV (Test Level X – asymmetrical)
Signal4 kV (Test Level X – asymmetrical)
CommentsCriterion A
Surge voltage load (surge)EN 61000-4-5
Input2 kV (Test Level 4 – symmetrical)
4 kV (Test Level 4 – asymmetrical)
Output1 kV (Test Level 3 – symmetrical)
2 kV (Test Level 3 – asymmetrical)
Signal0.5 kV (Test Level 2 – symmetrical)
CommentsCriterion A
Conducted interferenceEN 61000-4-6
I/O/Sasymmetrical
Frequency range0.15 MHz … 80 MHz
Voltage10 V (Test Level 3)
CommentsCriterion A
Power frequency magnetic fieldEN 61000-4-8
Frequency16.67 Hz
50 Hz
60 Hz
Test field strength100 A/m
Additional text60 s
CommentsCriterion A
Frequency50 Hz
60 Hz
Frequency range50 Hz … 60 Hz
Test field strength1 kA/m
Additional text3 s
Frequency0 Hz
Test field strength300 A/m
Additional textDC, 60 s
Voltage dipsEN 61000-4-11
Voltage100 V AC
Frequency60 Hz
Voltage dip70 %
Number of periods0.5 / 1 / 30 periods
Additional textTest Level 2
CommentsCriterion A
Voltage dip40 %
Number of periods5 / 10 / 50 periods
Additional textTest Level 2
CommentsCriterion B
Voltage dip0 %
Number of periods0.5 / 1 / 5 / 50 periods
Additional textTest Level 2
CommentsCriterion B
Pulse-shape magnetic fieldEN 61000-4-9
Test field strength1000 A/m
CommentsCriterion A
Attenuated sinusoidal oscillations (ring wave)EN 61000-4-12
Input2 kV (symmetrical)
4 kV (asymmetrical)
CommentsCriterion A
Asymmetrical conducted disturbance variablesEN 61000-4-16
Test level 116.67 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
Voltage30 V (10 s)
Test level 216.67 Hz 50 Hz 60 Hz (Test Level 2)
Voltage300 V (1 s)
CommentsCriterion A
Attenuated oscillating waveEN 61000-4-18
Voltage1 kV (symmetrical)
2.5 kV (asymmetrical)
1 kV (symmetrical)
CommentsCriterion A
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Criterion CTemporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.

Environmental Product Compliance

REACh SVHCLead 7439-92-1

Title

Go to Top