SIMATIC ET 200SP – AI Energy Meter 400/480V AC ST – Siemens Analog Input Modules

USD $ 251.37USD $ 276.20

SKU: N/A

Siemens Analog Input Modules ET 200SP Product Specifications:

General information
Article number6ES7134-6PA01-0BD0
Product type designationAI energy meter 400VAC ST
Firmware versionV3.0
usable BaseUnitsBU type D0
Product function
● Voltage measurementYes
— with voltage transformerNo
● Current measurementYes
— without current transformerNo
— with current transformerYes
● Energy measurementYes
● Frequency measurementYes
● Power measurementYes
● Active power measurementYes
● Reactive power measurementYes
● I&M dataYes; I&M0 to I&M3
● Isochronous modeNo
Engineering with
●     STEP 7 TIA Portal configurable/integrated from versionV13 SP1
●     STEP 7 configurable/integrated from versionV5.5 SP4 and higher
●     PROFIBUS from GSD version/GSD revisionGSD Revision 5
●     PROFINET from GSD version/GSD revisionV2.3
Operating mode
● cyclic measurementYes
● acyclic measurementYes
● Acyclic measured value accessYes
● Fixed measured value setsYes
● Freely definable measured value setsNo
CiR – Configuration in RUN
Reparameterization possible in RUNYes
Calibration possible in RUNNo
Installation type/mounting
Mounting positionany
Supply voltage
Design of the power supplySupply via voltage measurement channel L1
Rated value (AC)100 – 240 V AC
permissible range, lower limit (AC)90 V
permissible range, upper limit (AC)264 V
Line frequency
● permissible range, lower limit47 Hz
● permissible range, upper limit63 Hz
Power loss
Power loss, typ.0.6 W
Address area
Address space per module
● Address space per module, max.44 byte; 32 byte input / 12 byte output
Hardware configuration
Automatic encoding
● Mechanical coding elementYes
● Type of mechanical coding elementtype C
Time of day
Operating hours counter
● presentNo
Analog inputs
Cycle time (all channels), typ.50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data)
Interrupts/diagnostics/status information
Alarms
● Diagnostic alarmYes
● Limit value alarmNo
● Hardware interruptNo
Diagnostics indication LED
● Monitoring of the supply voltage (PWR-LED)Yes
● Channel status displayYes; green LED
● for channel diagnosticsYes; red Fn LED
● for module diagnosticsYes; green/red DIAG LED
Integrated Functions
Measuring functions
● Measuring procedure for voltage measurementTRMS
● Measuring procedure for current measurementTRMS
● Type of measured value acquisitionseamless
● Curve shape of voltageSinusoidal or distorted
● Buffering of measured variablesNo
● Parameter length38 byte
● Bandwidth of measured value acquisition2 kHz; Harmonics: 39 / 50 Hz, 32 / 60 Hz
Measuring range
— Frequency measurement, min.45 Hz
— Frequency measurement, max.65 Hz
Measuring inputs for voltage
— Measurable line voltage between phase and neutral conductor230 V
— Measurable line voltage between the line conductors
— Measurable line voltage between phase and neutral conductor, min.400 V
— Measurable line voltage between phase and neutral conductor, max.90 V
— Measurable line voltage between the line conductors, min.264 V
— Measurable line voltage between the line conductors, max.155 V
— Internal resistance line conductor and neutral conductor460 V
— Power consumption per phase3.4 MΩ
— Impulse voltage resistance 1,2/50µs20 mW
— Measurement category for voltage1 kV
measurement in accordance with IEC 61010-2030CAT II; CAT III in case of guaranteed protection level of 1.5 kV
Measuring inputs for current
— measurable relative current (AC), min.5 %; Relative to the secondary rated current; 1 A, 5 A
— measurable relative current (AC), max.100 %; Relative to the secondary rated current; 1 A, 5 A
— Continuous current with AC, maximum permissible5:00 AM
— Apparent power consumption per phase for measuring range 5 A0.6 VA
— Rated value short-time withstand current restricted to 1 s100 A
— Input resistance measuring range 0 to 5 A25 mΩ; At the terminal
— Surge strength10 A; for 1 minute
— Zero point suppressionParameterizable: 20 … 250 mA, default 50 mA
Accuracy class according to IEC 61557-12
— Measured variable voltage0.5
— Measured variable current0.5
— Measured variable apparent power1
— Measured variable active power1
— Measured variable reactive power1
— Measured variable power factor0.5
— Measured variable active energy1
— Measured variable reactive energy2
— Measured variable phase angle±1 °; not covered by IEC 61557-12
— Measured variable frequency0.05
Potential separation
Potential separation channels
● between the channels and backplane busYes; 3 700V AC (type test) CAT III
Isolation
Isolation tested with2 300V AC for 1 min. (type test)
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.0 °C
● horizontal installation, max.60 °C
● vertical installation, min.0 °C
● vertical installation, max.50 °C
Dimensions
Width20 mm
Height73 mm
Depth58 mm
Weights
Weight, approx.45 g
Other
Data for selecting a current transformer
● Burden power current transformer x/1A, min. ● Burden power current transformer x/5A, min.As a function of cable length and cross section, see device manual
As a function of cable length and cross section, see device manual

 

 

General information
Article number6ES7134-6PA20-0BD0
Product type designationAI Energy Meter 480VAC ST
Firmware versionV4.0
● FW update possibleYes
usable BaseUnitsBU type D0
Supported power supply systemsTT, TN
Product function
● Voltage measurementYes
— without voltage transformerYes
— with voltage transformerYes
● Current measurementYes
— without current transformerNo
— with current transformerYes
— With Rogowski coilNo
— With current-voltage-converterNo
● Energy measurementYes
● Frequency measurementYes
● Power measurementYes
● Active power measurementYes
● Reactive power measurementYes
● Power factor measurementYes
● Active factor measurementNo
● Reactive power compensationNo
● Line analysisNo
● I&M dataYes; I&M0 to I&M3
● Isochronous modeNo
Engineering with
●     STEP 7 TIA Portal configurable/integrated from versionV13 SP1
●     STEP 7 configurable/integrated from versionV5.5 SP4 and higher
●     PROFIBUS from GSD version/GSD revisionGSD Revision 5
●     PROFINET from GSD version/GSD revisionV2.3
Operating mode
● Cyclic measured value accessYes
● Acyclic measured value accessYes
● Fixed measured value setsYes
● Freely definable measured value setsYes
CiR – Configuration in RUN
Reparameterization possible in RUNYes
Calibration possible in RUNYes
Installation type/mounting
Mounting positionany
Supply voltage
Design of the power supplySupply via voltage measurement channel L1
Rated value (AC)AC 100 – 277 V
permissible range, lower limit (AC)90 V
permissible range, upper limit (AC)293 V
Line frequency
● permissible range, lower limit47 Hz
● permissible range, upper limit63 Hz
Power loss
Power loss, typ.0.6 W
Address area
Address space per module
● Inputs256 byte
● Outputs12 byte
Hardware configuration
Automatic encodingYes
● Mechanical coding elementYes
● Type of mechanical coding elementtype C
Selection of BaseUnit for connection variants
● 2-wire connectionBU type D0, BU20-P12+A0+0B
Time of day
Operating hours counter
● presentYes
Analog inputs
Cycle time (all channels), typ.50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data)
Cable length
● unshielded, max.200 m
Analog value generation for the inputs
Measurement principleSigma Delta
Sampling frequency, max.1 024 kHz
Interrupts/diagnostics/status information
Alarms
● Diagnostic alarmYes
● Limit value alarmYes
● Hardware interruptYes; Monitoring of up to 16 freely selectable process values (exceeding or undershooting of value)
Diagnostics indication LED
● Monitoring of the supply voltage (PWR-LED)Yes
● Channel status displayYes; green LED
● for channel diagnosticsYes; red Fn LED
● for module diagnosticsYes; green/red DIAG LED
Integrated Functions
Measuring functions
● Measuring procedure for voltage measurementTRMS
● Measuring procedure for current measurementTRMS
● Type of measured value acquisitionseamless
● Curve shape of voltageSinusoidal or distorted
● Buffering of measured variablesYes
● Parameter length74 byte
● Bandwidth of measured value acquisition2 kHz; Harmonics: 39 / 50 Hz, 32 / 60 Hz
Measuring range
— Frequency measurement, min.45 Hz
— Frequency measurement, max.65 Hz
Measuring inputs for voltage
— Measurable line voltage between phase and neutral conductor277 V
— Measurable line voltage between the line conductors480 V
— Measurable line voltage between phase and neutral conductor, min.
— Measurable line voltage between phase and neutral conductor, max.90 V
— Measurable line voltage between the line conductors, min.293 V
— Measurable line voltage between the line conductors, max.155 V
— Internal resistance line conductor and neutral conductor508 V
— Power consumption per phase3.4 MΩ
— Impulse voltage resistance 1,2/50µs20 mW
— Measurement category for voltage1 kV
measurement in accordance with IEC 61010-2030CAT II; CAT III in case of guaranteed protection level of 1.5 kV
Measuring inputs for current
— measurable relative current (AC), min.1 %; Relative to the secondary rated current 5 A
— measurable relative current (AC), max.100 %; Relative to the secondary rated current 5 A
— Continuous current with AC, maximum permissible5:00 AM
— Apparent power consumption per phase for measuring range 5 A0.6 VA
— Rated value short-time withstand current restricted to 1 s100 A
— Input resistance measuring range 0 to 5 A25 mΩ; At the terminal
— Surge strength10 A; for 1 minute
— Zero point suppressionParameterizable: 2 … 250 mA, default 50 mA
Accuracy class according to IEC 61557-12
— Measured variable voltage0,2
— Measured variable current0,2
— Measured variable apparent power0.5
— Measured variable active power0.5
— Measured variable reactive power1
— Measured variable power factor0.5
— Measured variable active energy0.5
— Measured variable reactive energy1
— Measured variable neutral current0.5; calculated
— Measured variable phase angle±1 °; not covered by IEC 61557-12
— Measured variable frequency0.05
Potential separation
Potential separation channels
● between the channelsNo
● between the channels and backplane busYes; 3 700V AC (type test) CAT III
Isolation
Isolation tested with2 300V AC for 1 min. (type test)
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.0 °C
● horizontal installation, max.60 °C
● vertical installation, min.0 °C
● vertical installation, max.50 °C
Altitude during operation relating to sea level
● Ambient air temperature-barometric pressurealtitudeOn request: Ambient temperatures lower than 0 °C (without condensation) and/or installation altitudes greater than 2 000 m
Dimensions
Width20 mm
Height73 mm
Depth58 mm
Weights
Weight, approx.45 g
Other
Data for selecting a voltage transformer
● Secondary side, max.296 V
Data for selecting a current transformer
● Burden power current transformer x/1A, min. ● Burden power current transformer x/5A, min.As a function of cable length and cross section, see device manual
As a function of cable length and cross section, see device manual

 

WeightN/A
DimensionsN/A