Siemens Power Modules SIMATIC ET 200S Product Specifications:

Article number6ES7138-4CF03-0AB06ES7138-4CF42-0AB0
ET200S, Powermod. PM-E F PM, DC24VET200S, Powermod. PM-E F PP, DC24V
Supply voltage
Load voltage L+
● Rated value (DC)24 V24 V
● Reverse polarity protectionNoNo
Input current
From load voltage L+ (no load), typ.100 mA100 mA
from backplane bus 24 V DC, max.28 mA28 mA
Power loss
Power loss, typ.4 W4 W
Address area
Address space per module
● Inputs5 byte5 byte
● Outputs5 byte5 byte
Digital outputs
Number of digital outputs21; Relays
Short-circuit protectionYes; ElectronicNo
● Response threshold, typ.Response threshold (short-circuit): 5 to 12 A; response threshold (external short-circuit to ground): 5 to 12 A; response threshold (external short-circuit to P potential): 25 to 45 A
Limitation of inductive shutdown voltage toL+ (-2x 47 V)
Controlling a digital inputNoYes
Switching capacity of the outputs
● on lamp load, max.10 W100 W
Load resistance range
● lower limit12 Ω
● upper limit1 kΩ
Output voltage
● for signal “1”, min.L+ (-2,0 V), current sourcing switch: L+ (-1,5 V), voltage drop on current sinking switch: max. 0.5 V
Output current
● for signal “1” rated value2 A
● for signal “1” permissible range for 0 to 60 °C, min.20 mA
● for signal “1” permissible range for 0 to 60 °C, max.2.4 A
● for signal “0” residual current, max.0.5 mA
Parallel switching of two outputs
● for upratingNo
● for redundant control of a loadNo
Switching frequency
● with resistive load, max.30 Hz2 Hz
● with inductive load, max.0.1 Hz0.1 Hz; with inductive load to IEC 60947-5-1, DC-13 / AC-15
● on lamp load, max.10 Hz2 Hz
Total current of the outputs (per group)
horizontal installation
— up to 40 °C, max.10 A10 A
— up to 55 °C, max.7 A8 A
— up to 60 °C, max.6 A7 A
vertical installation
— up to 40 °C, max.6 A8 A
Relay outputs
Switching capacity of contacts
— with resistive load, up to 50 °C, max.10 A10 A
Cable length
● shielded, max.200 m
● unshielded, max.200 m
Interrupts/diagnostics/status information
Diagnostics functionYesYes
Diagnoses
● Diagnostic information readableYesYes
● Wire-breakYesNo
● Short-circuitYesYes
● missing load voltageYesYes
Diagnostics indication LED
● Rated load voltage PWR (green)YesYes
● Group error SF (red)YesYes
● Status indicator digital output (green)YesYes
Potential separation
Potential separation digital outputs
● between the channelsNoNo
● between the channels and backplane busYesYes
● Between the channels and load voltage L+NoNo
Isolation
Isolation tested with500 V DC500 V DC
Standards, approvals, certificates
Highest safety class achievable in safety mode
● acc. to EN 95444
● Performance level according to ISO 13849-1ee
● SIL acc. to IEC 61508Up to SIL 3With Std-DO: Max. SIL 2, without Std-DO max. SIL 3 depending on configuration
Dimensions
Width30 mm30 mm
Height81 mm81 mm
Depth52 mm52 mm
Weights
Weight, approx.88 g80 g
WeightN/A
DimensionsN/A

Title