inosakiInosakiinosaki

Contact Us
sales@365accountings.com   

SIMATIC ET 200SP – Analog Input Basic / Standard Modules – Siemens

USD $ 183.12USD $ 284.55

SKU: N/A

The distributed I/O system ET 200SP offers a comprehensive portfolio of analog inputs, modules with standard functionality (ST) as well as enhanced functions (HF High Feature / HS High Speed)

Especially for price sensitive applications there are modules available that offer basic functionality (BA).

Option of connecting current, voltage and resistance sensors, as well as thermocouples.

The most common modules are also available in packs of ten, which avoids packaging material and speeds up unpacking.

The High Speed Analog Input Module AI 2xU/I 2-/4-wire HS offers oversampling as enhanced functioanality.

Siemens Analog Input Modules ET 200SP Product Specifications:

Article number6ES7134-6GF00-0AA16ES7134-6FB00-0BA16ES7134-6FF00-0AA16ES7134-6HD01-0BA16ES7134-6GB00-0BA1
ET 200SP, AI 8XI 2-/4-Wire BasicET 200SP, AI 2xU Standard, PU 1ET 200SP, AI 8xU BasicET 200SP, AI 4xU/I 2-Wire ST, PU 1ET 200SP, AI 2xI 2-/4-Wire ST, PU 1
General information
Product type designationAI 8xI 2-/4-wire BAAI 2xU STAI 8xU BAAI 4x U/I 2-wireAI 2xI 2-/4-wire ST
HW functional statusfrom FS04from FS04from FS04From FS02from FS04
Firmware version
● FW update possibleYesYesYesYesYes
usable BaseUnitsBU type A0, A1BU type A0, A1BU type A0, A1BU type A0, A1BU type A0, A1
Color code for module-specific color identification plateCC01CC00CC02CC03CC05
Product function
● I&M dataYes; I&M0 to I&M3Yes; I&M0 to I&M3Yes; I&M0 to I&M3Yes; I&M0 to I&M3Yes; I&M0 to I&M3
● Isochronous modeNoNoNoNoNo
● Measuring range scalableNoNoNoNoNo
Engineering with
● STEP 7 TIA Portal configurable/integrated from versionV13 SP1V13 SP1V13 SP1V14 / –V13 SP1
● STEP 7 configurable/integrated from versionV5.5 SP3 / –V5.5 SP3 / –V5.5 SP3 / –V5.6 and higherV5.5 SP3
● PCS 7 configurable/integrated from versionV8.1 SP1
● PROFIBUS from GSD version/GSD revisionOne GSD file each, Revision 3 and 5 and higherOne GSD file each, Revision 3 and 5 and higherOne GSD file each, Revision 3 and 5 and higherOne GSD file each, Revision 3 and 5 and higherOne GSD file each, Revision 3 and 5 and higher
● PROFINET from GSD version/GSD revisionGSDML V2.3GSDML V2.3GSDML V2.3GSDML V2.3V2.3 / –
Operating mode
● OversamplingNoNoNoNoNo
● MSINoNoNoNoNo
CiR – Configuration in RUN
Reparameterization possible in RUNYesYesYesYesYes
Calibration possible in RUNNoNoNoNoNo
Supply voltage
Rated value (DC)24 V24 V24 V24 V24 V
permissible range, lower limit (DC)19.2 V19.2 V19.2 V19.2 V19.2 V
permissible range, upper limit (DC)28.8 V28.8 V28.8 V28.8 V28.8 V
Reverse polarity protectionYesYesYesYesYes
Input current
Current consumption, max.25 mA; without sensor supply37 mA25 mA37 mA; without sensor supply45 mA; without sensor supply
Encoder supply
24 V encoder supply
● 24 VYesNoYesYes
● Short-circuit protectionYesYesYes
● Output current, max.0.7 A; total current of all encoders/channels20 mA; max. 50 mA per channel for a duration < 10 s50 mA; Total current for both channels (two-wire)
Additional 24 V encoder supply
● 24 VNoYes
● Short-circuit protectionYes; Module-wise
● Output current, max.200 mA; Total current for both channels (four-wire)
Power loss
Power loss, typ.0.7 W; Without encoder supply voltage0.9 W0.7 W0.85 W; Without encoder supply voltage1.1 W
Address area
Address space per module
● Address space per module, max.16 byte4 byte; + 1 byte for QI information16 byte8 byte; + 1 byte for QI information4 byte; + 1 byte for QI information
Hardware configuration
Automatic encodingYesYesYesYesYes
● Mechanical coding elementYesYesYesYesYes
● Type of mechanical coding elementType AType Atype BType AType A
Selection of BaseUnit for connection variants
● 1-wire connectionBU type A0, A1BU type A0, A1BU type A0, A1BU type A0, A1
● 2-wire connectionBU type A0, A1BU type A0, A1BU type A0, A1BU type A0, A1BU type A0, A1
● 4-wire connectionBU type A0, A1 + potential distributor moduleBU type A0, A1
Analog inputs
Number of analog inputs8; Single-ended28; Single-ended4; Differential inputs2
● For current measurement82
● For voltage measurement28
permissible input voltage for voltage input (destruction limit), max.30 V30 V30 V
permissible input current for current input (destruction limit), max.50 mA50 mA50 mA
Cycle time (all channels), min.1 ms; per channel500 µs1 ms; per channelSum of the basic conversion times and additional processing times (depending on the parameterization of the active channels)500 µs
Input ranges (rated values), voltages
● 0 to +10 VYes; 15 bitYes; 15 bitYes; 15 bit
— Input resistance (0 to 10 V)180 kΩ100 kΩ120 kΩ
● 1 V to 5 VYes; 15 bitYes; 15 bit
— Input resistance (1 V to 5 V)180 kΩ120 kΩ
● -10 V to +10 VYes; 16 bit incl. signYes; 16 bit incl. signYes; 16 bit incl. sign
— Input resistance (-10 V to +10 V)180 kΩ100 kΩ120 kΩ
● -5 V to +5 VYes; 16 bit incl. signYes; 16 bit incl. sign
— Input resistance (-5 V to +5 V)180 kΩ120 kΩ
Input ranges (rated values), currents
● 0 to 20 mAYesYes; 15 bitYes; 15 bit
— Input resistance (0 to 20 mA)100 Ω; 15 bit100 Ω; + approx. 0.7 V diode forward voltage130 Ω; 90 ohms with two wires
● -20 mA to +20 mAYesYes; 16 bit incl. sign
— Input resistance (-20 mA to +20 mA)100 Ω; 16 bit incl. sign130 Ω
● 4 mA to 20 mAYesYes; 15 bitYes; 15 bit
— Input resistance (4 mA to 20 mA)100 Ω; 15 bit100 Ω; + approx. 0.7 V diode forward voltage130 Ω; 90 ohms with two wires
Cable length
● shielded, max.200 m200 m200 m1 000 m; 200 m for voltage measurement1 000 m
Analog value generation for the inputs
Measurement principleSigma Deltaintegrating (Sigma-Delta)Sigma Delta
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max.16 bit16 bit16 bit16 bit16 bit
● Integration time, parameterizableYesYesYesYesYes
● Interference voltage suppression for interference frequency f1 in Hz16.67 / 50 / 60 / 4 800 (16.67 / 50 / 60)16.6 / 50 / 60 Hz / off16.67 / 50 / 60 / 4 800 (16.67 / 50 / 60)16.6 / 50 / 60 Hz16.6 / 50 / 60 Hz / off
● Conversion time (per channel)180 / 60 / 50 / 0.625 (67.5 / 22.5 / 18.75) ms50 ms @ 60 Hz, 60 ms @ 50 Hz, 180 ms @ 16.6 Hz, 250 µs without filter180 / 60 / 50 / 0.625 (67.5 / 22.5 / 18.75) ms180 / 60 / 50 ms50 ms @ 60 Hz, 60 ms @ 50 Hz, 180 ms @ 16.6 Hz, 500 µs without filter
Smoothing of measured values
● Number of smoothing levels4; None; 4/8/16 times44; None; 4/8/16 times4; None; 4/8/16 times4
● parameterizableYesYesYesYesYes
● Step: NoneYes; 1x cycle timeYes; 1x conversion time
● Step: lowYes; 4x cycle timeYes; 4x conversion time
● Step: MediumYes; 8x cycle timeYes; 8x conversion time
● Step: HighYes; 16x cycle timeYes; 16x conversion time
Encoder
Connection of signal encoders
● for voltage measurementNoYesYesYes
● for current measurement as 2-wire transducerYesYesYes
— Burden of 2-wire transmitter, max.650 Ω650 Ω650 Ω
● for current measurement as 4-wire transducerYesNoNoYes
Errors/accuracies
Linearity error (relative to input range), (+/-)0.01 %0.01 %0.01 %0.01 %0.01 %
Temperature error (relative to input range), (+/-)0.005 %/K0.005 %/K0.005 %/K0.005 %/K0.005 %/K
Crosstalk between the inputs, min.50 dB-50 dB-50 dB50 dB-50 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.05 %0.05 %0.05 %0.05 %0.05 %
Operational error limit in overall temperature range
● Voltage, relative to input range, (+/-)0.5 %0.5 %0.5 %
● Current, relative to input range, (+/-)0.5 %0.5 %0.5 %
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input range, (+/-)0.3 %0.3 %0.3 %
● Current, relative to input range, (+/-)0.3 %0.3 %0.3 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
● Series mode interference (peak value of interference < rated value of input range), min.70 dB; With conversion time 67.5 / 22.5 / 18.75 ms: 40 dB70 dB70 dB; With conversion time 67.5 / 22.5 / 18.75 ms: 40 dB70 dB70 dB
● Common mode voltage, max.10 V10 V10 V
● Common mode interference, min.90 dB90 dB90 dB
Interrupts/diagnostics/status information
Diagnostics functionYesYesYesYesYes
Alarms
● Diagnostic alarmYesYesYesYesYes
● Limit value alarmNoNoNoNoNo
Diagnoses
● Monitoring the supply voltageYesYesYesYesYes
● Wire-breakYes; at 4 to 20 mANoNoYes; at 4 to 20 mAYes; at 4 to 20 mA
● Short-circuitYes; Sensor supply to M; module by moduleYes; at 1 to 5 VNoYes; with 1 to 5 V or 2-wire mode: Short-circuit of the encoder supply to ground or of an input to the encoder supplyYes; Short-circuit of the encoder supply
● Group errorYesYesYesYesYes
● Overflow/underflowYesYesYesYesYes
Diagnostics indication LED
● Monitoring of the supply voltage (PWR-LED)Yes; green LEDYes; green PWR LEDYes; green PWR LEDYes; green LEDYes; green PWR LED
● Channel status displayYes; green LEDYes; green LEDYes; green LEDYes; green LEDYes; green LED
● for channel diagnosticsNoNoNoNoNo
● for module diagnosticsYes; green/red DIAG LEDYes; green/red DIAG LEDYes; green/red DIAG LEDYes; green/red LEDYes; green/red DIAG LED
Potential separation
Potential separation channels
● between the channelsNoNoNoYes; channel group-specific between 2-wire current input group and voltage input groupNo
● between the channels and backplane busYesYesYesYesYes
● between the channels and the power supply of the electronicsNoYesNoYes; only for voltage inputsYes
Permissible potential difference
between the inputs (UCM)10 Vpp10 V DC10 Vpp
Isolation
Isolation tested with707 V DC (type test)707 V DC (type test)707 V DC (type test)707 V DC (type test)707 V DC (type test)
Standards, approvals, certificates
Suitable for applications according to AMS 2750Yes; Declaration of Conformity, see online support entry 109757262
Suitable for applications according to CQI-9Yes
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.-30 °C; < 0 °C as of FS04-30 °C; < 0 °C as of FS04-30 °C; < 0 °C as of FS04-30 °C; < 0 °C as of FS02-30 °C; < 0 °C as of FS04
● horizontal installation, max.60 °C60 °C60 °C60 °C60 °C
● vertical installation, min.-30 °C; < 0 °C as of FS04-30 °C; < 0 °C as of FS04-30 °C; < 0 °C as of FS04-30 °C; < 0 °C as of FS02-30 °C; < 0 °C as of FS04
● vertical installation, max.50 °C50 °C50 °C50 °C50 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual5 000 m; Restrictions for installation altitudes > 2 000 m, see manual5 000 m; Restrictions for installation altitudes > 2 000 m, see manual5 000 m; Restrictions for installation altitudes > 2 000 m, see manual5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Dimensions
Width15 mm15 mm15 mm15 mm15 mm
Height73 mm73 mm73 mm73 mm73 mm
Depth58 mm58 mm58 mm58 mm58 mm
Weights
Weight, approx.31 g31 g31 g31 g32 g
WeightN/A
DimensionsN/A

Title