Scalable and cost-optimized configuration of a ET 200SP station is achieved by a comprehensive portfolio of digital and analog IO modules.

SIMATIC ET 200SP is about 50% narrower than other distributed peripheries. With its height of 115 millimeters, the system can accommodate 16 channels with single-wire connection (without AUX-plugs). For a 3-wire connection with AUX-plugs the height for 8 channels is 140 millimeters. The depth is 75 millimeters. In order to keep its small size, the power module for load group formation is integrated into the system of SIMATIC ET 200SP.

The peripheral modules are labelled with different colored squares to identify easily the type of module.

Siemens Digital Output Modules ET 200SP Product Specifications:

Article number6ES7132-6BF61-0AA06ES7132-6BH00-0AA06ES7132-6BF01-0AA06ES7132-6BH01-0BA06ES7132-6BF01-0BA0
ET 200SP, DQ 8x 24VDC/0,5A SINK BA, PU 1ET 200SP, DQ 16X24VDC/0,5A BA, PU 1ET 200SP, DQ 8x 24V DC/0,5A Basic, PU 1ET 200SP, DQ 16x 24V DC/0,5A ST, PU 1ET 200SP, DQ 8x 24V DC/0,5A ST, PU 1
General information
Product type designationDQ 8x24VDC/0,5A SNK BADQ 16x24VDC/0.5A BADQ 8x24VDC/0.5A BADQ 16x24VDC/0.5A STDQ 8x24VDC/0.5A ST
HW functional statusFrom FS02From FS03From FS02From FS03From FS02
Firmware versionV0.0V0.0V0.0V0.0V0.0
● FW update possibleNoNoNoNoNo
usable BaseUnitsBU type A0BU type A0BU type A0BU type A0BU type A0
Color code for module-specific color identification plateCC01CC00CC02CC00CC02
Product function
● I&M dataYes; I&M0 to I&M3Yes; I&M0 to I&M3Yes; I&M0 to I&M3Yes; I&M0 to I&M3Yes; I&M0 to I&M3
● Isochronous modeNoNoNoNoNo
Engineering with
● STEP 7 TIA Portal configurable/integrated from versionV14V14V14V14V14
● STEP 7 configurable/integrated from versionV5.5 SP3STEP 7 V5.5 or higherV5.5 SP3V5.5 SP3V5.5 SP3 or higher
● PCS 7 configurable/integrated from versionV8.1 SP1V8.1 SP1
● PROFIBUS from GSD version/GSD revisionOne GSD file each, Revision 3 and 5 and higherOne GSD file each, Revision 3 and 5 and higherOne GSD file each, Revision 3 and 5 and higherOne GSD file each, Revision 3 and 5 and higherOne GSD file each, Revision 3 and 5 and higher
● PROFINET from GSD version/GSD revisionGSDML V2.3GSDML V2.3GSDML V2.3GSDML V2.3GSDML V2.3
Operating mode
● DQYesYesYesYesYes
● DQ with energy-saving functionNoNoNoNoNo
● PWMNoNoNoNoNo
● OversamplingNoNoNoNoNo
● MSONoNoNoNoNo
Redundancy
● Redundancy capabilityYes
Supply voltage
Rated value (DC)24 V24 V24 V24 V24 V
permissible range, lower limit (DC)19.2 V19.2 V19.2 V19.2 V19.2 V
permissible range, upper limit (DC)28.8 V28.8 V28.8 V28.8 V28.8 V
Reverse polarity protectionYesYesYesYes
Input current
Current consumption, max.55 mA; without load45 mA; without load60 mA; without load35 mA; without load
output voltage / header
Rated value (DC)24 V24 V24 V24 V24 V
Power loss
Power loss, typ.1.5 W1 W1 W1 W1 W
Address area
Address space per module
● Address space per module, max.1 byte2 byte; + 2 bytes for QI information1 byte; + 1 byte for QI information
● Outputs1 byte2 byte
Hardware configuration
Automatic encodingYesYesYesYesYes
● Mechanical coding elementYesYesYesYesYes
● Type of mechanical coding elementtype BType AType AType AType A
Selection of BaseUnit for connection variants
● 1-wire connectionBU type A0BU type A0BU type A0BU type A0
● 2-wire connectionBU type A0 + Potential distributor moduleBU type A0BU type A0 + Potential distributor moduleBU type A0
● 3-wire connectionBU type A0 + Potential distributor moduleBU type A0 with AUX terminals or potential distributor moduleBU type A0 + Potential distributor moduleBU type A0 with AUX terminals or potential distributor module
● 4-wire connectionBU type A0 + Potential distributor moduleBU type A0 + Potential distributor moduleBU type A0 + Potential distributor moduleBU type A0 + Potential distributor module
Digital outputs
Type of digital outputSource output (PNP, current-sourcing)Source output (PNP, current-sourcing)Source output (PNP, current-sourcing)Source output (PNP, current-sourcing)Source output (PNP, current-sourcing)
Number of digital outputs8168168
Current-sinkingYesNoNo
Current-sourcingYesYesYesYes
Digital outputs, parameterizableYesYesYesYesYes
Short-circuit protectionYesYesYes; per channel, electronicYesYes
● Response threshold, typ.1.5 A1.4 A; 0.7 to 1.9 A1 A1 A; 0.7 to 1.3 A1 A
Open-circuit detectionNoYes
Limitation of inductive shutdown voltage toTyp. 47 VTyp. L+ (-53 V)Typ. L+ (-50 V)Typ. L+ (-50 V)Typ. L+ (-50 V)
Controlling a digital inputYesYesYesYesYes
Switching capacity of the outputs
● with resistive load, max.0.5 A0.5 A0.5 A0.5 A0.5 A
● on lamp load, max.5 W5 W5 W5 W5 W
Load resistance range
● lower limit48 Ω48 Ω48 Ω48 Ω48 Ω
● upper limit3 400 Ω100 kΩ100 kΩ12 kΩ12 kΩ
Output voltage
● for signal “1”, min.L+ (-0.8 V)
Output current
● for signal “1” rated value0.5 A0.5 A0.5 A0.5 A0.5 A
● for signal “1” permissible range, max.0.5 A0.5 A0.5 A
● for signal “0” residual current, max.5 µA30 µA10 µA0.1 mA0.1 mA
Output delay with resistive load
● “0” to “1”, typ.80 µs; at rated load50 µs
● “0” to “1”, max.300 µs150 µs; at rated load100 µs; at rated load50 µs; at rated load
● “1” to “0”, typ.100 µs; at rated load100 µs
● “1” to “0”, max.600 µs200 µs; at rated load150 µs; at rated load100 µs; at rated load
Parallel switching of two outputs
● for upratingNoNoNoNoNo
● for redundant control of a loadYesYesYesYesYes
Switching frequency
● with resistive load, max.100 Hz100 Hz100 Hz100 Hz100 Hz
● with inductive load, max.0.5 Hz2 Hz2 Hz2 Hz2 Hz
● on lamp load, max.10 Hz10 Hz10 Hz10 Hz10 Hz
Total current of the outputs
● Current per channel, max.0.5 A0.5 A0.5 A0.5 A0.5 A
● Current per module, max.4 A8 A4 A8 A4 A
Total current of the outputs (per module)
horizontal installation
— up to 40 °C, max.8 A
— up to 50 °C, max.6 A
— up to 60 °C, max.4 A8 A4 A4 A4 A
vertical installation
— up to 30 °C, max.8 A
— up to 40 °C, max.6 A
— up to 50 °C, max.4 A8 A4 A4 A4 A
Cable length
● shielded, max.1 000 m1 000 m1 000 m1 000 m1 000 m
● unshielded, max.600 m600 m600 m600 m600 m
Interrupts/diagnostics/status information
Diagnostics functionYesYesYesYesYes
Substitute values connectableYesYesYesYesYes
Alarms
● Diagnostic alarmYesYesYesYesYes
Diagnoses
● Monitoring the supply voltageYesYesYesYesYes
● Wire-breakNoNoNoYes; Module-wiseYes; Module-wise
● Short-circuitNoNoNo
● Short-circuit to MYes; Module-wiseYes; Module-wise
● Short-circuit to L+Yes; Module-wiseYes; Module-wise
● Group errorYesYesYesYesYes
Diagnostics indication LED
● Monitoring of the supply voltage (PWR-LED)Yes; green PWR LEDYes; green PWR LEDYes; green PWR LEDYes; green PWR LEDYes; green PWR LED
● Channel status displayYes; green LEDYes; green LEDYes; green LEDYes; green LEDYes; green LED
● for channel diagnosticsNoNoNoNoNo
● for module diagnosticsYes; green/red DIAG LEDYes; green/red DIAG LEDYes; green/red DIAG LEDYes; green/red DIAG LEDYes; green/red DIAG LED
Potential separation
Potential separation channels
● between the channelsNoNoNoNoNo
● between the channels and backplane busYesYesYesYesYes
● between the channels and the power supply of the electronicsNoNo
Isolation
Isolation tested with707 V DC (type test)707 V DC (type test)707 V DC (type test)707 V DC (type test)707 V DC (type test)
Standards, approvals, certificates
Suitable for safety functionsNoNoNoNoNo
Suitable for safety-related tripping of standard modulesNoYes; see FAQ Entry ID: 39198632Yes; see FAQ Entry ID: 39198632Yes; see FAQ Entry ID: 39198632
Highest safety class achievable in safety mode
● Performance level according to ISO 13849-1PL dPL dPL d
● SIL acc. to IEC 61508SIL 2SIL 2SIL 2
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.-25 °C-30 °C-30 °C; < 0 °C as of FS02-30 °C; < 0 °C as of FS03-30 °C; < 0 °C as of FS02
● horizontal installation, max.60 °C60 °C60 °C60 °C60 °C
● vertical installation, min.-25 °C-30 °C-30 °C; < 0 °C as of FS02-30 °C; < 0 °C as of FS03-30 °C; < 0 °C as of FS02
● vertical installation, max.50 °C50 °C50 °C50 °C50 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual5 000 m; Restrictions for installation altitudes > 2 000 m, see manual5 000 m; Restrictions for installation altitudes > 2 000 m, see manual5 000 m; Restrictions for installation altitudes > 2 000 m, see manual5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Dimensions
Width15 mm15 mm15 mm15 mm15 mm
Height73 mm73 mm73 mm73 mm73 mm
Depth58 mm58 mm58 mm58 mm58 mm
Weights
Weight, approx.30 g30 g30 g30 g30 g

 

WeightN/A
DimensionsN/A

Title