inosakiInosakiinosaki

Contact Us
sales@365accountings.com   

SIMATIC S7-1200 – CPU 1214FC – Siemens PLC

USD $ 524.57

SKU: 6ES7214-1AF40-0XB0

Siemens PLC model SIMATIC S7-1200 controller is at the core of our offering for simple but highly precise automation tasks. The SIMATIC S7-1200 controller is modular and compact, versatile, a secure investment, and is perfectly suited to a whole range of applications.

Siemens PLC S7-1200 CPUs with Safety Integrated handle both standard and safety-related tasks. A compact design with integrated IO, communication interfaces that meet the highest industry requirements and a range of powerful integrated technological functions make this controller an integral part of a comprehensive automation solution. Siemens plc software are available for win cc find out more.

Siemens PLC S7-1200 Product Specifications:

Article number6ES7214-1AF40-0XB0
CPU 1214 FC, DC/DC/DC, 14DI/10DO/2AI
General information
Product type designationCPU 1214FC DC/DC/DC
Firmware versionV4.5
Engineering with
● Programming packageSTEP 7 V17 or higher
Supply voltage
Rated value (DC)
● 24 V DCYes
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Load voltage L+
● Rated value (DC)24 V
● permissible range, lower limit (DC)20.4 V
● permissible range, upper limit (DC)28.8 V
Input current
Current consumption (rated value)500 mA; CPU only
Current consumption, max.1 500 mA; CPU with all expansion modules
Inrush current, max.12 A; at 28.8 V
I²t0.5 A²·s
Output current
for backplane bus (5 V DC), max.1 600 mA; Max. 5 V DC for SM and CM
Encoder supply
24 V encoder supply
● 24 VL+ minus 4 V DC min.
Power loss
Power loss, typ.12 W
Memory
Work memory
● integrated125 kbyte
● expandableNo
Load memory
● integrated4 Mbyte
● Plug-in (SIMATIC Memory Card), max.with SIMATIC memory card
Backup
● presentYes
● maintenance-freeYes
● without batteryYes
CPU processing times
for bit operations, typ.0.08 µs; / instruction
for word operations, typ.1.7 µs; / instruction
for floating point arithmetic, typ.2.3 µs; / instruction
CPU-blocks
Number of blocks (total)DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used
OB
● Number, max.Limited only by RAM for code
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.14 kbyte
Flag
● Size, max.8 kbyte; Size of bit memory address area
Local data
● per priority class, max.16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB
Address area
Process image
● Inputs, adjustable1 kbyte
● Outputs, adjustable1 kbyte
Hardware configuration
Number of modules per system, max.3 comm. modules, 1 signal board, 8 signal modules
Time of day
Clock
● Hardware clock (real-time)Yes
● Backup time480 h; Typical
● Deviation per day, max.±60 s/month at 25 °C
Digital inputs
Number of digital inputs14; Integrated
● of which inputs usable for technological functions6; HSC (High Speed Counting)
Source/sink inputYes
Number of simultaneously controllable inputs
all mounting positions
— up to 40 °C, max.14
Input voltage
● Rated value (DC)24 V
● for signal “0”5 V DC at 1 mA
● for signal “1”15 V DC at 2.5 mA
Input delay (for rated value of input voltage)
for standard inputs
— parameterizable0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four
— at “0” to “1”, min.0.2 ms
— at “0” to “1”, max.12.8 ms
for interrupt inputs
— parameterizableYes
for technological functions
— parameterizableSingle phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz
Cable length
● shielded, max.500 m; 50 m for technological functions
● unshielded, max.300 m; for technological functions: No
Digital outputs
Number of digital outputs10
● of which high-speed outputs4; 100 kHz Pulse Train Output
Limitation of inductive shutdown voltage toL+ (-48 V)
Switching capacity of the outputs
● with resistive load, max.0.5 A
● on lamp load, max.5 W
Output voltage
● for signal “0”, max.0.1 V; with 10 kOhm load
● for signal “1”, min.20 V
Output current
● for signal “1” rated value0.5 A
● for signal “0” residual current, max.0.1 mA
Output delay with resistive load
● “0” to “1”, max.1 µs
● “1” to “0”, max.5 µs
Switching frequency
● of the pulse outputs, with resistive load, max.100 kHz
Relay outputs
● Number of relay outputs0
● Number of operating cycles, max.
Cable length
● shielded, max.500 m
● unshielded, max.150 m
Analog inputs
Number of analog inputs2
Input ranges
● VoltageYes
Input ranges (rated values), voltages
● 0 to +10 VYes
— Input resistance (0 to 10 V)≥100k ohms
Cable length
● shielded, max.100 m; twisted and shielded
Analog outputs
Number of analog outputs0
Output ranges, current
● 0 to 20 mA
Analog value generation for the inputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max.10 bit
● Integration time, parameterizableYes
● Conversion time (per channel)625 µs
Analog value generation for the outputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max.
Encoder
Connectable encoders
● 2-wire sensorYes
1. Interface
Interface typePROFINET
IsolatedYes
automatic detection of transmission rateYes
AutonegotiationYes
AutocrossingYes
Interface types
● RJ 45 (Ethernet)Yes
● Number of ports1
● integrated switchNo
Protocols
● PROFINET IO ControllerYes
● PROFINET IO DeviceYes
● SIMATIC communicationYes
● Open IE communicationYes; Optionally also encrypted
● Web serverYes
● Media redundancyNo
PROFINET IO Controller
● Transmission rate, max.100 Mbit/s
Services
— PG/OP communicationYes; encryption with TLS V1.3 pre-selected
— Isochronous modeNo
— IRTNo
— PROFIenergyNo
— Prioritized startupYes
— Number of IO devices with prioritized startup, max.16
— Number of connectable IO Devices, max.16
— Number of connectable IO Devices for RT, max.16
— of which in line, max.16
— Activation/deactivation of IO DevicesYes
— Number of IO Devices that can be simultaneously activated/deactivated, max.8
— Updating timeThe minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.
PROFINET IO Device
Services
— PG/OP communicationYes; encryption with TLS V1.3 pre-selected
— Isochronous modeNo
— IRTNo
— PROFIenergyYes
— Shared deviceYes
— Number of IO Controllers with shared device, max.2
Protocols
Supports protocol for PROFINET IOYes
PROFIsafeYes
PROFIBUSYes; CM 1243-5 (master) or CM 1242-5 (slave) required
OPC UAYes; OPC UA Server
AS-InterfaceYes; CM 1243-2 required
Protocols (Ethernet)
● TCP/IPYes
● DHCPNo
● SNMPYes
● DCPYes
● LLDPYes
Redundancy mode
Media redundancy
— MRP
— MRPD
SIMATIC communication
● S7 routing
Open IE communication
● TCP/IPYes
— Data length, max.8 kbyte
● ISO-on-TCP (RFC1006)Yes
— Data length, max.8 kbyte
● UDPYes
— Data length, max.1 472 byte
Web server
● supportedYes
● User-defined websitesYes
OPC UA
● Runtime license requiredYes; “Basic” license required
● OPC UA ServerYes; data access (read, write, subscribe), method call, runtime license required
— Application authenticationAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication“anonymous” or by user name & password
— Number of sessions, max.10
— Number of subscriptions per session, max.50
— Sampling interval, min.100 ms
— Publishing interval, min.200 ms
— Number of server methods, max.20
— Number of monitored items, max.1 000
— Number of server interfaces, max.2
— Number of nodes for user-defined server interfaces, max.2 000
Further protocols
● MODBUSYes
communication functions / header
S7 communication
● supportedYes
● as serverYes
● as clientYes
● User data per job, max.See online help (S7 communication, user data size)
Number of connections
● overallPG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 64 max
Test commissioning functions
Status/control
● Status/control variableYes
● Variablesinputs/outputs, bit memories, DBs, peripheral I/Os (without fail-safe), times, counters
Forcing
● ForcingYes; peripheral inputs/outputs (without fail-safe)
Diagnostic buffer
● presentYes
Traces
● Number of configurable Traces2
● Memory size per trace, max.512 kbyte
Interrupts/diagnostics/status information
Diagnostics indication LED
● RUN/STOP LEDYes
● ERROR LEDYes
● MAINT LEDYes
Integrated Functions
Frequency measurementYes
controlled positioningYes
Number of position-controlled positioning axes, max.8
Number of positioning axes via pulse-direction interface4; With integrated outputs
PID controllerYes
Number of alarm inputs4
Number of pulse outputs4
Limit frequency (pulse)100 kHz
Potential separation
Potential separation digital inputs
● Potential separation digital inputsNo
● between the channels, in groups of1
Potential separation digital outputs
● Potential separation digital outputsYes
● between the channelsNo
● between the channels, in groups of1
EMC
Interference immunity against discharge of static electricity
● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2Yes
— Test voltage at air discharge8 kV
— Test voltage at contact discharge6 kV
Interference immunity to cable-borne interference
● Interference immunity on supply lines acc. to IEC 61000-4-4Yes
● Interference immunity on signal cables acc. to IEC 61000-4-4Yes
Interference immunity against voltage surge
● Interference immunity on supply lines acc. to IEC 61000-4-5Yes
Interference immunity against conducted variable disturbance induced by high-frequency fields
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-6Yes
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areasYes; Group 1
● Limit class B, for use in residential areasYes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011
Degree and class of protection
IP degree of protectionIP20
Standards, approvals, certificates
CE markYes
UL approvalYes
cULusYes
FM approvalYes
RCM (formerly C-TICK)Yes
KC approvalYes
Marine approvalYes
Highest safety class achievable in safety mode
● Performance level according to ISO 13849-1PLe
● SIL acc. to IEC 61508SIL 3
Ambient conditions
Free fall
● Fall height, max.0.3 m; five times, in product package
Ambient temperature during operation
● min.0 °C
● max.55 °C; Number of simultaneously activated inputs or outputs 4 or 3 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 8 or 6 at 55 °C horizontal or 45 °C vertical
● horizontal installation, min.0 °C
● horizontal installation, max.55 °C
● vertical installation, min.0 °C
● vertical installation, max.45 °C
Ambient temperature during storage/transportation
● min.-40 °C
● max.70 °C
Air pressure acc. to IEC 60068-2-13
● Operation, min.795 hPa
● Operation, max.1 080 hPa
● Storage/transport, min.660 hPa
● Storage/transport, max.1 080 hPa
Altitude during operation relating to sea level
● Installation altitude, min.-1 000 m
● Installation altitude, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Relative humidity
● Operation, max.95 %; no condensation
Vibrations
● Vibration resistance during operation acc. to IEC 60068-2-62 g (m/s²) wall mounting, 1 g (m/s²) DIN rail
● Operation, tested according to IEC 60068-2-6Yes
Shock testing
● tested according to IEC 60068-2-27Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms
Pollutant concentrations
● SO2 at RH < 60% without condensationS02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free
configuration / header
configuration / programming / header
Programming language
— LADYes; incl. failsafe
— FBDYes; incl. failsafe
— SCLYes
Know-how protection
● User program protection/password protectionYes
● Copy protectionYes
● Block protectionYes
Access protection
● protection of confidential configuration dataYes
● Protection level: Write protectionYes
● Protection level: Read/write protectionYes
● Protection level: Complete protectionYes
programming / cycle time monitoring / header
● adjustableYes
Dimensions
Width110 mm
Height100 mm
Depth75 mm
Weights
Weight, approx.415 g
Weight0.364 kg
Dimensions11.2 × 11.6 × 8.5 cm

Title