The design and functionality of the SIMATIC PM 1507 single-phase load power supply (PM = power module) with automatic range selection of the input voltage makes it an optimal match to the SIMATIC S7-1500 PLC. It supplies the S7-1500 system components such as CPU, system power supply (PS), I/O circuits of the input and output modules and, if necessary, the sensors and actuators with 24 V DC.

Siemens Power Supplies PM 1507 Product Specifications:

Article number6EP1332-4BA006EP1333-4BA00
ProductS7-1500 PM1507S7-1500 PM1507
Power supply, type24 V/3 A24 V/8 A
Input
type of the power supply network1-phase AC1-phase AC
supply voltage at AC
● initial valueAutomatic range selectionAutomatic range selection
supply voltage
● 1 at AC rated value120 V120 V
● 2 at AC rated value230 V230 V
input voltage
● 1 at AC85 … 132 V85 … 132 V
● 2 at AC170 … 264 V170 … 264 V
design of input wide range inputNoNo
overvoltage overload capability2.3 × Vin rated, 1.3 ms2.3 × Vin rated, 1.3 ms
operating condition of the mains bufferingat Vin = 93/187 Vat Vin = 93/187 V
buffering time for rated value of the output current in the event of power failure minimum20 ms20 ms
operating condition of the mains bufferingat Vin = 93/187 Vat Vin = 93/187 V
line frequency
● 1 rated value50 Hz50 Hz
● 2 rated value60 Hz60 Hz
line frequency45 … 65 Hz45 … 65 Hz
input current
● at rated input voltage 120 V1.4 A3.7 A
● at rated input voltage 230 V0.8 A1.7 A
current limitation of inrush current at 25 °C maximum23 A62 A
duration of inrush current limiting at 25 °C
● maximum3 ms3 ms
I2t value maximum1.3 A²·s12 A²·s
fuse protection typeT 3,15 A/250 V (not accessible)T 6.3 A/250 V (not accessible)
● in the feederRecommended miniature circuit breaker: 10 A characteristic B or 6 A characteristic CRecommended miniature circuit breaker: 16 A characteristic B or 10 A characteristic C
Output
voltage curve at outputControlled, isolated DC voltageControlled, isolated DC voltage
output voltage at DC rated value24 V24 V
output voltage
● at output 1 at DC rated value24 V24 V
relative overall tolerance of the voltage1 %1 %
relative control precision of the output voltage
● on slow fluctuation of input voltage0.1 %0.1 %
● on slow fluctuation of ohm loading0.1 %0.1 %
residual ripple
● maximum50 mV50 mV
voltage peak
● maximum150 mV150 mV
product function output voltage adjustableNoNo
display version for normal operationLED green for 24 V OK; LED red for error; LED yellow for stand-byLED green for 24 V OK; LED red for error; LED yellow for stand-by
behavior of the output voltage when switching onNo overshoot of Vout (soft start)No overshoot of Vout (soft start)
response delay maximum1.5 s1.5 s
voltage increase time of the output voltage
● typical10 ms10 ms
output current
● rated value3 A8 A
● rated range0 … 3 A0 … 8 A
supplied active power typical72 W192 W
short-term overload current
● on short-circuiting during the start-up typical12 A35 A
● at short-circuit during operation typical12 A35 A
duration of overloading capability for excess current
● on short-circuiting during the start-up70 ms70 ms
● at short-circuit during operation70 ms70 ms
product feature
● bridging of equipmentYesYes
number of parallel-switched equipment resources for increasing the power22
Efficiency
efficiency in percent87 %90 %
power loss [W]
● at rated output voltage for rated value of the output current typical11 W21 W
Closed-loop control
relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical0.1 %0.1 %
relative control precision of the output voltage load step of resistive load 50/100/50 % typical1 %2 %
relative control precision of the output voltage at load step of resistive load 10/90/10 % typical3 %3 %
setting time
● load step 10 to 90% typical5 ms5 ms
● load step 90 to 10% typical5 ms5 ms
● maximum5 ms5 ms
Protection and monitoring
design of the overvoltage protectionAdditional control loop, limitation (closed loop control) at < 28.8 VAdditional control loop, limitation (closed loop control) at < 28.8 V
response value current limitation3.15 … 3.6 A8.4 … 9.6 A
response value current limitation typical3.4 A9 A
property of the output short-circuit proofYesYes
design of short-circuit protectionElectronic shutdown, automatic restartElectronic shutdown, automatic restart
display version for overload and short circuit
Safety
galvanic isolation between input and outputYesYes
galvanic isolationSafety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 and EN 61131-2Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 and EN 61131-2
operating resource protection classClass IClass I
leakage current
● maximum3.5 mA3.5 mA
● typical0.4 mA1.3 mA
protection class IPIP20IP20
Approvals
certificate of suitability
● CE markingYesYes
● UL approvalYes; cULus-Listed (UL 508, CSA C22.2 No. 142), File E143289Yes; cULus-Listed (UL 508, CSA C22.2 No. 142), File E143289
● CSA approvalYes; cULus-Listed (UL 508, CSA C22.2 No. 142), File E143289Yes; cULus-Listed (UL 508, CSA C22.2 No. 142), File E143289
● cCSAus, Class 1, Division 2NoNo
● ATEXYes; ATEX (EX) II 3G Ex nA nC IIC T4 GcYes; ATEX (EX) II 3G Ex nA nC IIC T3 Gc
certificate of suitability
● relating to ATEXIECEx Ex nA nC IIC T4 Gc; ATEX (EX) II 3G Ex nA nC IIC T4 Gc; cULus (ANSI/ISA 12.12.01, CSA C22.2 No.213) Class I, Div. 2, Group ABCD, T4, File E330455IECEx Ex nA nC IIC T3 Gc; ATEX (EX) II 3G Ex nA nC IIC T3 Gc; cULus (ANSI/ISA 12.12.01, CSA C22.2 No.213) Class I, Div. 2, Group ABCD, T3, File E330455
● IECExYes; IECEx Ex nA nC IIC T4 GcYes; IECEx Ex nA nC IIC T3 Gc
● NEC Class 2NoNo
● ULhazloc approvalYesYes
● FM registrationYes; Class I, Div. 2, Group ABCD, T4Yes; Class I, Div. 2, Group ABCD, T4
type of certification CB-certificateYesYes
certificate of suitability
● EAC approvalYesYes
certificate of suitability shipbuilding approvalYesYes
shipbuilding approvalABS, BV, DNV GLABS, BV, DNV GL
Marine classification association
● American Bureau of Shipping Europe Ltd. (ABS)YesYes
● French marine classification society (BV)YesYes
● DNV GLYesYes
● Lloyds Register of Shipping (LRS)NoNo
● Nippon Kaiji Kyokai (NK)NoNo
EMC
standard
● for emitted interferenceEN 55022 Class BEN 55022 Class B
● for mains harmonics limitationEN 61000-3-2EN 61000-3-2
● for interference immunityEN 61000-6-2EN 61000-6-2
environmental conditions
ambient temperature
● during operation0 … 60 °C; with natural convection0 … 60 °C; with natural convection
● during transport-40 … +85 °C-40 … +85 °C
● during storage-40 … +85 °C-40 … +85 °C
environmental category according to IEC 60721Climate class 3K3, 5 … 95% no condensationClimate class 3K3, 5 … 95% no condensation
Mechanics
type of electrical connectionScrew-/spring clamp connectionScrew-/spring clamp connection
● at inputL, N, PE: 1 screw terminal each for 0.5 … 2.5 mm²L, N, PE: 1 screw terminal each for 0.5 … 2.5 mm²
● at outputL+, M: 2 spring-loaded terminals each for 0.5 to 2.5 mm²L+, M: 2 spring-loaded terminals each for 0.5 to 2.5 mm²
product function
● removable terminal at inputYesYes
● removable terminal at outputYesYes
width of the enclosure50 mm75 mm
height of the enclosure147 mm147 mm
depth of the enclosure129 mm129 mm
required spacing
● top40 mm40 mm
● bottom40 mm40 mm
● left0 mm0 mm
● right0 mm0 mm
net weight0.45 kg0.74 kg
product feature of the enclosure housing can be lined upYesYes
fastening methodCan be mounted onto S7-1500 railCan be mounted onto S7-1500 rail
MTBF at 40 °C1 611 993 h1 362 918 h
other informationSpecifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)