SIMATIC S7-300 – CPU315T-3 PN/DP – Siemens PLC

USD $ 4,560.56

SKU: 6ES7315-7TJ10-0AB0

The CPU 315-3 PN/DP is used primarily in machines where a control with a large program memory coincides with high processing speed and motion control requirements

Siemens PLC S7-300 Product Specifications:

Article number6ES7315-7TJ10-0AB0
CPU315T-3 PN/DP, 384KB
General information
HW functional status1
Firmware versionCPU: V3.2; integrated technology V4.1.5
Product function
● Isochronous modeYes; Via PROFIBUS DP or PROFINET interface
Engineering with
● Programming packageSTEP 7 V5.5 SP2 or higher and S7-Technology option package V4.2 SP3
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
external protection for power supply lines (recommendation)2 A min.
Load voltage L+
● Rated value (DC)24 V
● Reverse polarity protectionYes
Digital outputs
— Rated value (DC)24 V; (2L+)
— Reverse polarity protectionNo; (2L+)
Input current
Current consumption (rated value)1 050 mA
Current consumption (in no-load operation), typ.230 mA
Inrush current, typ.6.5 A
I²t1 A²·s
Power loss
Power loss, typ.7.5 W
Memory
Work memory
● integrated384 kbyte
● expandableNo
Load memory
● Plug-in (MMC)Yes
● Plug-in (MMC), max.8 Mbyte
● Data management on MMC (after last programming), min.10 y
Backup
● presentYes; Guaranteed by MMC (maintenance-free)
● without batteryYes; Program and data
CPU processing times
for bit operations, typ.0.05 µs
for word operations, typ.0.09 µs
for fixed point arithmetic, typ.0.12 µs
for floating point arithmetic, typ.0.45 µs
CPU-blocks
Number of blocks (total)1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
● Number, max.1 024; Number range: 1 to 16000
● Size, max.64 kbyte
FB
● Number, max.1 024; Number range: 0 to 7999
● Size, max.64 kbyte
FC
● Number, max.1 024; Number range: 0 to 7999
● Size, max.64 kbyte
OB
● Number, max.see instruction list
● Size, max.64 kbyte
● Number of free cycle OBs1; OB 1
● Number of time alarm OBs1; OB 10
● Number of delay alarm OBs2; OB 20, 21
● Number of cyclic interrupt OBs4; OB 32, 33, 34, 35
● Number of process alarm OBs1; OB 40
● Number of DPV1 alarm OBs3; OB 55, 56, 57
● Number of isochronous mode OBs1; OB 61 – isochronous mode is possible either on DP or PROFINET IO (not simultaneously)
● Number of technology synchronous alarm OBs1; OB 65
● Number of startup OBs1; OB 100
● Number of asynchronous error OBs6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)
● Number of synchronous error OBs2; OB 121, 122
Nesting depth
● per priority class16
● additional within an error OB4
Counters, timers and their retentivity
S7 counter
● Number256
Retentivity
— adjustableYes
— lower limit0
— upper limit255
— presetZ 0 to Z 7
Counting range
— adjustableYes
— lower limit0
— upper limit999
IEC counter
● presentYes
● TypeSFB
● NumberUnlimited (limited only by RAM capacity)
S7 times
● Number256
Retentivity
— adjustableYes
— lower limit0
— upper limit255
— presetNo retentivity
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
● presentYes
● TypeSFB
● NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.128 kbyte
Flag
● Size, max.2 048 byte
● Retentivity availableYes; MB 0 to MB 2 047
● Retentivity presetMB 0 to MB 15
● Number of clock memories8; 1 memory byte
Data blocks
● Retentivity adjustableYes; via non-retain property on DB
● Retentivity presetYes
Local data
● per priority class, max.32 768 byte; Max. 2048 bytes per block
Address area
I/O address area
● Inputs2 048 byte
● Outputs2 048 byte
of which distributed
— Inputs2 048 byte
— Outputs2 048 byte
Process image
● Inputs2 048 byte
● Outputs2 048 byte
● Inputs, adjustable2 048 byte
● Outputs, adjustable2 048 byte
● Inputs, default128 byte
● Outputs, default128 byte
Default addresses of the integrated channels
— Digital inputs66
— Digital outputs66
Subprocess images
● Number of subprocess images, max.1; With PROFINET IO, the length of the user data is limited to 1600 bytes
Digital channels
● Inputs16 384
— of which central256
● Outputs16 384
— of which central256
Analog channels
● Inputs1 024
— of which central64
● Outputs1 024
— of which central64
Hardware configuration
Number of expansion units, max.0
Number of DP masters
● integrated2; 1 DP and 1 DP (drive)
● via CP2; for DP
Number of operable FMs and CPs (recommended)
● FM8
● CP, PtP8
● CP, LAN8
Rack
● Racks, max.1
● Modules per rack, max.8
Time of day
Clock
● Hardware clock (real-time)Yes
● retentive and synchronizableYes
● Backup time6 wk; At 40 °C ambient temperature
● Deviation per day, max.10 s; Typ.: 2 s
● Behavior of the clock following POWER-ONClock continues running after POWER OFF
● Behavior of the clock following expiry of backup periodthe clock continues at the time of day it had when power was switched off
Operating hours counter
● Number1
● Number/Number range0
● Range of values0 to 2^31 hours (when using SFC 101)
● Granularity1 h
● retentiveYes; Must be restarted at each restart
Clock synchronization
● supportedYes
● to MPI, masterYes
● to MPI, slaveYes
● to DP, masterYes
● to DP, slaveYes; Only time-of-day slave
● in AS, masterYes
● in AS, slaveYes
● on Ethernet via NTPYes; As client
Digital inputs
Number of digital inputs4
● of which inputs usable for technological functions4
Input characteristic curve in accordance with IEC 61131, type 1Yes
Number of simultaneously controllable inputs
horizontal installation
— up to 40 °C, max.4
— up to 60 °C, max.4
vertical installation
— up to 40 °C, max.4
Input voltage
● Rated value (DC)24 V
● for signal “0”-3 to +5V
● for signal “1”+15 to +30 V
Input current
● for signal “1”, typ.7 mA
Input delay (for rated value of input voltage)
for technological functions
— at “0” to “1”, max.10 µs; Typical
— at “1” to “0”, max.10 µs; Typical
Cable length
● shielded, max.1 000 m
Digital outputs
Number of digital outputs8
● of which high-speed outputs8
Functionsfor technology functions, e.g. high-speed cam switch signals
Short-circuit protectionYes
● Response threshold, typ.1 A
Limitation of inductive shutdown voltage to48 V
Controlling a digital inputNo
Switching capacity of the outputs
● on lamp load, max.5 W
Load resistance range
● lower limit48 Ω
● upper limit4 kΩ
Output voltage
● for signal “0”, max.3 V; (2L+)
● for signal “1”, min.Rated voltage -2.5 V
Output current
● for signal “1” rated value0.5 A
● for signal “1” permissible range for 0 to 60 °C, min.5 mA
● for signal “1” permissible range for 0 to 60 °C, max.0.6 A
● for signal “0” residual current, max.0.3 mA
Parallel switching of two outputs
● for upratingNo
● for redundant control of a loadNo
Switching frequency
● with resistive load, max.100 Hz
● with inductive load, max.0.2 Hz; According to IEC 60947-5-1, DC-13
● on lamp load, max.100 Hz
Total current of the outputs (per group)
horizontal installation
— up to 40 °C, max.4 A
— up to 60 °C, max.3 A
all other mounting positions
— up to 40 °C, max.4 A
Integrated high-speed cams
● Switching accuracy (+/-)70 µs
Cable length
● shielded, max.1 000 m
Analog inputs
Number of analog inputs0
Analog outputs
Number of analog outputs0
Encoder
Connectable encoders
● 2-wire sensorNo
Interfaces
Number of industrial Ethernet interfaces1
Number of PROFINET interfaces1
Number of RS 485 interfaces2
Number of RS 422 interfaces0
1. Interface
Interface typeIntegrated RS 485 interface
IsolatedYes
Interface types
● RS 485Yes
● Output current of the interface, max.200 mA
Protocols
● MPIYes
● PROFIBUS DP masterYes
● PROFIBUS DP slaveYes
● Point-to-point connectionNo
MPI
● Transmission rate, max.12 Mbit/s
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationYes
— S7 basic communicationYes
— S7 communicationYes
— S7 communication, as clientNo; but via CP and loadable FB
— S7 communication, as serverYes
PROFIBUS DP master
● Transmission rate, max.12 Mbit/s
● Number of DP slaves, max.124
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationYes; I blocks only
— S7 communicationYes
— S7 communication, as clientNo
— S7 communication, as serverYes
— EquidistanceYes
— Isochronous modeYes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO
— SYNC/FREEZEYes
— Activation/deactivation of DP slavesYes
— Number of DP slaves that can be simultaneously activated/deactivated, max.8
— Direct data exchange (slave-to-slave communication)Yes; as subscriber
— DPV1Yes
Address area
— Inputs, max.2 kbyte
— Outputs, max.2 kbyte
User data per DP slave
— Inputs, max.244 byte
— Outputs, max.244 byte
PROFIBUS DP slave
● Transmission rate, max.12 Mbit/s
● automatic baud rate searchYes; only with passive interface
● Address area, max.32
● User data per address area, max.32 byte
Services
— PG/OP communicationYes
— RoutingYes; Only with active interface
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
— S7 communication, as clientNo
— S7 communication, as serverYes; Connection configured on one side only
— Direct data exchange (slave-to-slave communication)Yes
— DPV1No
Transfer memory
— Inputs244 byte
— Outputs244 byte
2. Interface
Interface typeIntegrated RS 485 interface
IsolatedYes
Interface types
● RS 485Yes
● Output current of the interface, max.200 mA
Protocols
● MPINo
● PROFIBUS DP masterYes; DP(DRIVE)-Master
● PROFIBUS DP slaveNo
● Point-to-point connectionNo
PROFIBUS DP master
● Transmission rate, max.12 Mbit/s
● Number of DP slaves, max.64
Services
— PG/OP communicationNo
— RoutingNo
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationNo
— EquidistanceYes
— Isochronous modeYes
— SYNC/FREEZENo
— Activation/deactivation of DP slavesYes
— DPV1No
Address area
— Inputs, max.1 024 byte
— Outputs, max.1 024 byte
User data per DP slave
— Inputs, max.244 byte
— Outputs, max.244 byte
PROFIBUS DP slave
● GSD filehttp://support.automation.siemens.com in Product Support area
● Transmission rate, max.12 Mbit/s
3. Interface
Interface typePROFINET
IsolatedYes
automatic detection of transmission rateYes; 10/100 Mbit/s
AutonegotiationYes
AutocrossingYes
Change of IP address at runtime, supportedYes
Interface types
● RJ 45 (Ethernet)Yes
● Number of ports2
● integrated switchYes
Protocols
● MPINo
● PROFINET IO ControllerYes; Also simultaneously with IO-Device functionality
● PROFINET IO DeviceYes; Also simultaneously with IO Controller functionality
● PROFIBUS DP masterNo
● PROFIBUS DP slaveNo
● Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
● Web serverYes
● Media redundancyYes
PROFINET IO Controller
● Transmission rate, max.100 Mbit/s
Services
— PG/OP communicationYes
— RoutingYes
— S7 communicationYes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32
— Isochronous modeYes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO
— Shared deviceYes
— Prioritized startupYes
— Number of IO devices with prioritized startup, max.32
— Number of connectable IO Devices, max.128
— Of which IO devices with IRT, max.64
— of which in line, max.64
— Number of connectable IO Devices for RT, max.128
— of which in line, max.128
— Activation/deactivation of IO DevicesYes
— Number of IO Devices that can be simultaneously activated/deactivated, max.8
— IO Devices changing during operation (partner ports), supportedYes
— Number of IO Devices per tool, max.8
— Device replacement without swap mediumYes
— Send cycles250 µs, 500 µs, 1 ms, 2 ms, 4 ms
— Updating time250 µs to 512 ms (depending on the operating mode, see Manual “S7-300 CPU 31xC and CPU 31x, technical Data” for more details)
Address area
— Inputs, max.2 kbyte
— Outputs, max.2 kbyte
— User data consistency, max.1 024 byte
PROFINET IO Device
Services
— PG/OP communicationYes
— RoutingYes
— S7 communicationYes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32
— Isochronous modeNo
— IRTYes
— PROFIenergyYes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device
— Shared deviceYes
— Number of IO Controllers with shared device, max.2
Transfer memory
— Inputs, max.1 440 byte; Per IO Controller with shared device
— Outputs, max.1 440 byte; Per IO Controller with shared device
Submodules
— Number, max.64
— User data per submodule, max.1 024 byte
Open IE communication
● Number of connections, max.8
● Local port numbers used at the system end0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
● Keep-alive function, supportedYes
Protocols
PROFIsafeNo
Redundancy mode
Media redundancy
— Switchover time on line break, typ.200 ms; PROFINET MRP
— Number of stations in the ring, max.50
Open IE communication
● TCP/IPYes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.8
— Data length for connection type 01H, max.1 460 byte
— Data length for connection type 11H, max.32 768 byte
— several passive connections per port, supportedYes
● ISO-on-TCP (RFC1006)Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.8
— Data length, max.32 768 byte
● UDPYes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.8
— Data length, max.1 472 byte
Web server
● supportedYes
● User-defined websitesYes
● Number of HTTP clients5
communication functions / header
PG/OP communicationYes
Data record routingYes
Global data communication
● supportedYes
● Number of GD loops, max.8
● Number of GD packets, max.8
● Number of GD packets, transmitter, max.8
● Number of GD packets, receiver, max.8
● Size of GD packets, max.22 byte
● Size of GD packet (of which consistent), max.22 byte
S7 basic communication
● supportedYes
● User data per job, max.76 byte
● User data per job (of which consistent), max.76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
● supportedYes
● as serverYes
● as clientYes; via integrated PROFINET interface and loadable FB or via CP and loadable FB
● User data per job, max.See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5 compatible communication
● supportedYes; via CP and loadable FC
Number of connections
● overall16
● usable for PG communication15
— reserved for PG communication1
— adjustable for PG communication, min.1
— adjustable for PG communication, max.15
● usable for OP communication15
— reserved for OP communication1
— adjustable for OP communication, min.1
— adjustable for OP communication, max.15
● usable for S7 basic communication14
— reserved for S7 basic communication0
— adjustable for S7 basic communication, min.0
— adjustable for S7 basic communication, max.14
● usable for S7 communication14
— reserved for S7 communication0
— adjustable for S7 communication, min.0
— adjustable for S7 communication, max.14
● total number of instances, max.32
● usable for routingX1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.
S7 message functions
Number of login stations for message functions, max.16; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messagesYes
simultaneously active Alarm-S blocks, max.300
Test commissioning functions
Status blockYes; Up to 2 simultaneously
Single stepYes
Number of breakpoints4; without continuation
Status/control
● Status/control variableYes
● VariablesInputs, outputs, memory bits, DB, times, counters
● Number of variables, max.30
— of which status variables, max.30
— of which control variables, max.14
Forcing
● ForcingYes
● Forcing, variablesInputs, outputs
● Number of variables, max.10
Diagnostic buffer
● presentYes
● Number of entries, max.500
— adjustableNo
— of which powerfail-proof100; Only the last 100 entries are retained
● Number of entries readable in RUN, max.499
— adjustableYes; From 10 to 499
— preset10
Service data
● can be read outYes
Interrupts/diagnostics/status information
AlarmsNo
Diagnostics functionNo
Diagnostics indication LED
● Status indicator digital input (green)Yes
● Status indicator digital output (green)Yes
Potential separation
Potential separation digital inputs
● between the channels and backplane busYes
Potential separation digital outputs
● between the channels and backplane busYes
Isolation
Isolation tested with500 V DC
Ambient conditions
Ambient temperature during operation
● min.0 °C
● max.60 °C
configuration / header
Configuration software
● STEP 7Yes; STEP 7 V5.5 SP2 or higher and S7-Technology option package V4.2 SP3
configuration / programming / header
● Command setsee instruction list
● Nesting levels8
● System functions (SFC)see instruction list
● System function blocks (SFB)see instruction list
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCYes
— GRAPHYes
— HiGraph®Yes
Know-how protection
● User program protection/password protectionYes
● Block encryptionYes; With S7 block Privacy
Dimensions
Width120 mm
Height125 mm
Depth130 mm
Weights
Weight, approx.640 g
Weight0.718 kg
Dimensions13.1 × 15.5 × 12.8 cm