SIMATIC S7-400H – CPU 412-5H Central Processing Unit – Siemens PLC

USD $ 4,930.80

SKU: 6ES7412-5HK06-0AB0

The CPU 412-5H can be used for the SIMATIC S7-400H and S7-400F/FH. It enables the establishment of an S7-400H high-availability system. It can also be used for the S7-400F/FH fail-safe automation system in conjunction with the F runtime license.

The integrated PROFIBUS DP interfaces enable direct connection as master to the PROFIBUS DP fieldbus.

The integrated PROFINET interface with switch functionality forms the basis for providing 2 externally accessible PROFINET ports. In this way, linear or ring structures can be implemented.

Siemens PLC S7-400H Product Specifications:

Article number6ES7412-5HK06-0AB0
CPU412-5H PN/DP, 1MB F. S7-400H/F/FH
General information
Product type designationCPU 412-5H PN/DP
HW functional status1
Firmware versionV6.0
Product function
● Isochronous modeNo
Engineering with
● Programming packageAs of STEP 7 V5.5 SP2 with HF1
CiR – Configuration in RUN
CiR synchronization time, basic load100 ms
CiR synchronization time, time per I/O byte0 µs
Supply voltage
Rated value (DC)Power supply via system power supply
Input current
from backplane bus 5 V DC, typ.1.6 A
from backplane bus 5 V DC, max.1.9 A
from backplane bus 24 V DC, max.150 mA; 150 mA per DP interface
from interface 5 V DC, max.90 mA; At each DP interface
Power loss
Power loss, typ.7.5 W
Memory
Type of memoryRAM
Work memory
● integrated1 Mbyte
● integrated (for program)512 kbyte
● integrated (for data)512 kbyte
● expandableNo
Load memory
● expandable FEPROMYes; with Memory Card (FLASH)
● expandable FEPROM, max.64 Mbyte
● integrated RAM, max.512 kbyte
● expandable RAMYes
● expandable RAM, max.64 Mbyte
Backup
● presentYes
● with batteryYes; all data
● without batteryNo
Battery
Backup battery
● Backup current, typ.180 µA; Valid up to 40°C
● Backup current, max.1 000 µA
● Backup time, max.Dealt with in the module data manual with the secondary conditions and the factors of influence
● Feeding of external backup voltage to CPU5 V DC to 15 V DC
CPU processing times
for bit operations, typ.31.25 ns
for word operations, typ.31.25 ns
for fixed point arithmetic, typ.31.25 ns
for floating point arithmetic, typ.62.5 ns
CPU-blocks
DB
● Number, max.6 000; Number range: 1 to 16000
● Size, max.64 kbyte
FB
● Number, max.3 000; Number range: 0 to 7999
● Size, max.64 kbyte
FC
● Number, max.3 000; Number range: 0 to 7999
● Size, max.64 kbyte
OB
● Number, max.see instruction list
● Size, max.64 kbyte
● Number of free cycle OBs1; OB 1
● Number of time alarm OBs4; OB 10-13
● Number of delay alarm OBs4; OB 20-23
● Number of cyclic interrupt OBs4; OB 32-35
● Number of process alarm OBs4; OB 40-43
● Number of DPV1 alarm OBs3; OB 55-57
● Number of startup OBs2; OB 100, 102
● Number of asynchronous error OBs9; OB 80-88
● Number of synchronous error OBs2; OB 121, 122
Nesting depth
● per priority class24
● additional within an error OB1
Counters, timers and their retentivity
S7 counter
● Number2 048
Retentivity
— adjustableYes
— lower limit0
— upper limit2 047
— presetZ 0 to Z 7
Counting range
— lower limit0
— upper limit999
IEC counter
● presentYes
● TypeSFB
● NumberUnlimited (limited only by RAM capacity)
S7 times
● Number2 048
Retentivity
— adjustableYes
— lower limit0
— upper limit2 047
— presetNo times retentive
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
● presentYes
● TypeSFB
● NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.Total working and load memory (with backup battery)
Flag
● Size, max.8 192 byte
● Retentivity availableYes
● Retentivity presetMB 0 to MB 15
● Number of clock memories8; in 1 memory byte
Local data
● adjustable, max.16 kbyte
● preset8 kbyte
Address area
I/O address area
● Inputs8 kbyte
● Outputs8 kbyte
Process image
● Inputs, adjustable8 kbyte
● Outputs, adjustable8 kbyte
● Inputs, default256 byte
● Outputs, default256 byte
● consistent data, max.244 byte
● Access to consistent data in process imageYes
Subprocess images
● Number of subprocess images, max.15
Digital channels
● Inputs65 536
— of which central65 536
● Outputs65 536
— of which central65 536
Analog channels
● Inputs4 096
— of which central4 096
● Outputs4 096
— of which central4 096
Hardware configuration
Number of expansion units, max.21
connectable OPs47
MulticomputingNo
Interface modules
● Number of connectable IMs (total), max.6
● Number of connectable IM 460s, max.6
● Number of connectable IM 463s, max.4; Single mode only
Number of DP masters
● integrated2
● via CP10; CP 443-5 Extended
● Mixed mode IM + CP permittedNo
● via interface module0
Number of IO Controllers
● integrated1
● via CP0
Number of operable FMs and CPs (recommended)
● FMSee manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections
● CP, PtPSee manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections
● PROFIBUS and Ethernet CPs14; Of which max. 10 CP as DP master
Slots
● required slots2
Time of day
Clock
● Hardware clock (real-time)Yes
● retentive and synchronizableYes
● Resolution1 ms
● Deviation per day (buffered), max.1.7 s; Power off
● Deviation per day (unbuffered), max.8.6 s; Power on
Operating hours counter
● Number16
● Number/Number range0 to 15
● Range of valuesSFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 – 1 hours
● Granularity1 h
● retentiveYes
Clock synchronization
● supportedYes
● to MPI, masterYes
● to MPI, slaveYes
● to DP, masterYes
● to DP, slaveYes
● in AS, masterYes
● in AS, slaveYes
● on Ethernet via NTPYes; As client
Time difference in system when synchronizing via
● Ethernet, max.10 ms; Via NTP
● MPI, max.200 ms
Interfaces
Number of RS 485 interfaces2
Number of other interfaces2; Fiber-optic interface
Optical interfaceNo
1. Interface
Interface typeMPI/PROFIBUS DP
IsolatedYes
Interface types
● RS 485Yes
● Output current of the interface, max.150 mA
Protocols
● MPIYes
● PROFIBUS DP masterYes
● PROFIBUS DP slaveNo
MPI
● Number of connections32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
● Transmission rate, max.12 Mbit/s
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
— S7 communication, as clientYes
— S7 communication, as serverYes
PROFIBUS DP master
● Number of connections, max.16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
● Transmission rate, max.12 Mbit/s
● Number of DP slaves, max.32
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
— S7 communication, as clientYes
— S7 communication, as serverYes
— EquidistanceNo
— Isochronous modeNo
— SYNC/FREEZENo
— Activation/deactivation of DP slavesNo
— Direct data exchange (slave-to-slave communication)No
— DPV1Yes
Address area
— Inputs, max.2 kbyte
— Outputs, max.2 kbyte
User data per DP slave
— User data per DP slave, max.244 byte
— Inputs, max.244 byte
— Outputs, max.244 byte
— Slots, max.244
— per slot, max.128 byte
PROFIBUS DP slave
● Number of connectionsNo configuration of CPU as DP slave
2. Interface
Interface typePROFINET
IsolatedYes
automatic detection of transmission rateYes; Autosensing
AutonegotiationYes
AutocrossingYes
Change of IP address at runtime, supportedNo
Number of connection resources48
Interface types
● RJ 45 (Ethernet)Yes
● Number of ports2
● integrated switchYes
Protocols
● PROFINET IO ControllerYes
● PROFINET IO DeviceNo
● PROFINET CBANo
● PROFIBUS DP masterNo
● PROFIBUS DP slaveNo
● Open IE communicationYes
● Web serverNo
● Point-to-point connectionNo
● Media redundancyYes
PROFINET IO Controller
● Transmission rate, max.100 Mbit/s
Services
— PG/OP communicationYes
— S7 communicationYes
— Isochronous modeNo
— Shared deviceYes; Single mode only
— Prioritized startupNo
— Number of connectable IO Devices, max.256; In redundant mode via both interfaces
— Number of connectable IO Devices for RT, max.256
— of which in line, max.256
— Activation/deactivation of IO DevicesNo
— IO Devices changing during operation (partner ports), supportedNo
— Device replacement without swap mediumYes
— Send cycles250 µs, 500 µs, 1 ms, 2 ms, 4 ms
— Updating time250 µs to 512 ms, minimum value depends on the number of configured user data and the configured single or redundant mode
Address area
— Inputs, max.8 kbyte
— Outputs, max.8 kbyte
— User data consistency, max.1 024 byte
Open IE communication
● Number of connections, max.46
● Local port numbers used at the system end0, 20, 21, 25, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535
● Keep-alive function, supportedYes
3. Interface
Interface typePROFIBUS DP
Number of connection resources16
Interface types
● RS 485Yes
● Output current of the interface, max.150 mA
Protocols
● PROFIBUS DP masterYes
● PROFIBUS DP slaveNo
PROFIBUS DP master
● Number of connections, max.16
● Transmission rate, max.12 Mbit/s
● Number of DP slaves, max.64
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
— S7 communication, as clientYes
— S7 communication, as serverYes
— EquidistanceNo
— Isochronous modeNo
— SYNC/FREEZENo
— Activation/deactivation of DP slavesNo
— Direct data exchange (slave-to-slave communication)No
— DPV0Yes
— DPV1Yes
Address area
— Inputs, max.4 kbyte
— Outputs, max.4 kbyte
User data per DP slave
— User data per DP slave, max.244 byte
— Inputs, max.244 byte
— Outputs, max.244 byte
— Slots, max.244
— per slot, max.128 byte
4. Interface
Interface typePluggable synchronization submodule (FO)
Plug-in interface modulesSynchronization modules 6ES7960-1AA06-0XA0 or 6ES7960-1AB06-0XA0
5. Interface
Interface typePluggable synchronization submodule (FO)
Plug-in interface modulesSynchronization modules 6ES7960-1AA06-0XA0 or 6ES7960-1AB06-0XA0
Protocols
Redundancy mode
Media redundancy
— Switchover time on line break, typ.200 ms
— Number of stations in the ring, max.50
SIMATIC communication
● S7 routingYes
Open IE communication
● TCP/IPYes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.46
— Data length, max.32 kbyte
— several passive connections per port, supportedYes
● ISO-on-TCP (RFC1006)Yes; Via integrated PROFINET interface or CP 443-1 and loadable FBs
— Number of connections, max.46
— Data length, max.32 kbyte; 1 452 bytes via CP 443-1 Adv.
● UDPYes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.46
— Data length, max.1 472 byte
Web server
● supportedNo
Isochronous mode
EquidistanceNo
communication functions / header
PG/OP communicationYes
● Number of connectable OPs without message processing47
● Number of connectable OPs with message processing47; When using Alarm_S/SQ and Alarm_D/DQ
Data record routingYes
Global data communication
● supportedNo
S7 basic communication
● supportedNo
S7 communication
● supportedYes
● as serverYes
● as clientYes
● User data per job, max.64 kbyte
● User data per job (of which consistent), max.462 byte; 1 variable
S5 compatible communication
● supportedYes; (via CP max. 10 and FC AG_SEND and FC AG_RECV)
● User data per job, max.8 kbyte
● User data per job (of which consistent), max.240 byte
● Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.64/64
Standard communication (FMS)
● supportedYes; Via CP and loadable FB
Number of connections
● overall48
● usable for PG communication
— reserved for PG communication1
— adjustable for PG communication, max.0
● usable for OP communication
— reserved for OP communication1
— adjustable for OP communication, max.0
● usable for S7 basic communication
— reserved for S7 basic communication0
— adjustable for S7 basic communication, max.0
● usable for S7 communication
— reserved for S7 communication0
— adjustable for S7 communication, max.0
● usable for routing
— reserved for routing0
— adjustable for routing, max.0
S7 message functions
Number of login stations for message functions, max.47; Max. 47 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)
Symbol-related messagesNo
SCAN procedureNo
Program alarmsYes
Process diagnostic messagesYes
simultaneously active Alarm-S blocks, max.250; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks
Alarm 8-blocksYes
● Number of instances for alarm 8 and S7 communication blocks, max.600
● preset, max.300
Process control messagesYes
Number of archives that can log on simultaneously (SFB 37 AR_SEND)16
Test commissioning functions
Status blockYes
Single stepYes
Number of breakpoints16
Status/control
● Status/control variableYes; Up to 16 variable tables
● VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
● Number of variables, max.70
Forcing
● ForcingYes
● Forcing, variablesInputs/outputs, bit memories, distributed I/Os
● Number of variables, max.256
Diagnostic buffer
● presentYes
● Number of entries, max.3 200
— adjustableYes
— preset120
Service data
● can be read outYes
EMC
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areasYes
● Limit class B, for use in residential areasNo
configuration / header
Configuration software
● STEP 7Yes
configuration / programming / header
● Command setsee instruction list
● Nesting levels7
● Access to consistent data in process imageYes
● System functions (SFC)see instruction list
● System function blocks (SFB)see instruction list
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCYes
— GRAPHYes
— HiGraph®Yes
configuration / programming / number of simultaneously active SFC / header
— RD_REC8
— WR_REC8
— WR_PARM8
— PARM_MOD1
— WR_DPARM2
— DPNRM_DG8
— RDSYSST8
— DP_TOPOL1
configuration / programming / number of simultaneously active SFB / header
— RDREC8
— WRREC8
Know-how protection
● User program protection/password protectionYes
● Block encryptionYes; With S7 block Privacy
Dimensions
Width50 mm
Height290 mm
Depth219 mm
Weights
Weight, approx.995 g
Weight1.332 kg
Dimensions23.3 × 30 × 6.3 cm