Specifications

product name3RT2024-1AG24
product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
General technical data
size of contactorS0
product extensionNo
● function module for communication
● auxiliary switchNo
power loss [W] for rated value of the current0.9 W
● at AC in hot operating state
● at AC in hot operating state per pole0.3 W
● without load current share typical7.9 W
insulation voltage690 V
● of main circuit with degree of pollution 3 rated value
● of auxiliary circuit with degree of pollution 3 rated value690 V
surge voltage resistance6 kV
● of main circuit rated value
● of auxiliary circuit rated value6 kV
maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1400 V
shock resistance at rectangular impulse7,5g / 5 ms, 4,7g / 10 ms
● at AC
shock resistance with sine pulse11,8g / 5 ms, 7,4g / 10 ms
● at AC
mechanical service life (operating cycles)10 000 000
● of contactor typical
● of the contactor with added electronically optimized auxiliary switch block typical5 000 000
● of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (Date)10/1/2009
Ambient conditions
installation altitude at height above sea level maximum2 000 m
ambient temperature-25 … +60 °C
● during operation
● during storage-55 … +80 °C
relative humidity minimum10%
relative humidity at 55 °C according to IEC 60068-2-30 maximum95%
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
operating voltage
? at AC-3 rated value maximum690 V
? at AC-3e rated value maximum690 V
operational current
? at AC-1 at 400 V at ambient temperature 40 °C rated value40 A
? at AC-1
— up to 690 V at ambient temperature 40 °C rated value40 A
— up to 690 V at ambient temperature 60 °C rated value35 A
? at AC-3
— at 400 V rated value12A
— at 500 V rated value12A
— at 690 V rated value9A
? at AC-3e
— at 400 V rated value12A
— at 500 V rated value 12A12A
— at 690 V rated value 9A9A
? at AC-4 at 400 V rated value12.5 A
? at AC-5a up to 690 V rated value x12.5 A
? at AC-5b up to 400 V rated value9.9 A
? at AC-6a
— up to 230 V for current peak value n=20 rated value11.4 A
— up to 400 V for current peak value n=20 rated value11.4 A
— up to 500 V for current peak value n=20 rated value11.3 A
— up to 690 V for current peak value n=20 rated value9A
? at AC-6a2.9 A
— up to 230 V for current peak value n=30 rated value7.6 A
— up to 400 V for current peak value n=30 rated value7.6 A
— up to 500 V for current peak value n=30 rated value7.6 A
— up to 690 V for current peak value n=30 rated value7.6 A
minimum cross-section in main circuit at maximum AC-1 rated value10 mm²
operational current for approx. 200000 operating
cycles at AC-4
? at 400 V rated value 5.5 A
? at 690 V rated value 5.5 A
operational current
? at 1 current path at DC-1
— at 24 V rated value35 A
— at 110 V rated value4.5 A
— at 220 V rated value1A
— at 440 V rated value0.4 A
— at 600 V rated value0.25 A
? with 2 current paths in series at DC-1
— at 24 V rated value35 A
— at 110 V rated value35 A
— at 220 V rated value5A
— at 440 V rated value1A
— at 600 V rated value0.8 A
? with 3 current paths in series at DC-1
— at 24 V rated value35 A
— at 110 V rated value35 A
— at 220 V rated value35 A
— at 440 V rated value2.9 A
— at 600 V rated value1.4 A
? at 1 current path at DC-3 at DC-5
— at 24 V rated value20 A
— at 220 V rated value1A
— at 440 V rated value0.09 A
— at 600 V rated value0.06 A
? with 2 current paths in series at DC-3 at DC-5
— at 24 V rated value35 A
— at 110 V rated value15 A
— at 220 V rated value3A
— at 440 V rated value0.27 A
— at 600 V rated value0.16 A
? with 3 current paths in series at DC-3 at DC-5
— at 24 V rated value35 A
— at 110 V rated value35 A
— at 220 V rated value10A
— at 440 V rated value0.6 A
— at 600 V rated value0.6 A
operating power
? at AC-3
— at 230 V rated value3 kW
— at 400 V rated value5.5 kW
— at 500 V rated value 5.5 kW5.5 kW
— at 690 V rated value7.5 kW
? at AC-3e
— at 230 V rated value3 kW
— at 400 V rated value5.5 kW
— at 500 V rated value5.5 kW
— at 690 V rated value7.5 kW
operating power for approx. 200000 operating cycles at AC-4
? at 400 V rated value2.6 kW
? at 690 V rated value4.6 kW
operating apparent power at AC-6a
? up to 230 V for current peak value n=20 rated value4.5 kVA
? up to 400 V for current peak value n=20 rated value7.8 kVA
? up to 500 V for current peak value n=20 rated value9.8 kVA
? up to 690 V for current peak value n=20 rated value10.7 kVA
operating apparent power at AC-6a
? up to 230 V for current peak value n=30 rated value3 kVA
? up to 400 V for current peak value n=30 rated value5.2 kVA
? up to 500 V for current peak value n=30 rated value6.5 kVA
? up to 690 V for current peak value n=30 rated value9 kVA
short-time withstand current in cold operating state
up to 40 °C
? limited to 1 s switching at zero current maximum210 A; Use minimum cross-section acc. to AC-1 rated value
? limited to 5 s switching at zero current maximum 210 A; Use minimum cross-section acc. to AC-1 rated value
? limited to 10 s switching at zero current maximum170 A; Use minimum cross-section acc. to AC-1 rated value
? limited to 30 s switching at zero current maximum126 A; Use minimum cross-section acc. to AC-1 rated value
? limited to 60 s switching at zero current maximum 105 A; Use minimum cross-section acc. to AC-1 rated value
no-load switching frequency
? at AC5 000 1/h
operating frequency
? at AC-1 maximum1 000 1/h
? at AC-2 maximum1 000 1/h
? at AC-3 maximum1 000 1/h
? at AC-3e maximum1 000 1/h
? at AC-4 maximum300 1/h
Control circuit/ Control
type of voltage of the control supply voltage AC
control supply voltage at AC
? at 50 Hz rated value110 V
? at 60 Hz rated value110 V
operating range factor control supply voltage rated
value of magnet coil at AC
? at 50 Hz0.8 … 1.1
? at 60 Hz0.85 … 1.1
apparent pick-up power of magnet coil at AC
? at 50 Hz68 VA
? at 60 Hz67 VA
inductive power factor with closing power of the coil
? at 50 Hz0.72
? at 60 Hz0.74
apparent holding power of magnet coil at AC
? at 50 Hz7.9 VA
? at 60 Hz6.5 VA
inductive power factor with the holding power of the coil
? at 50 Hz0.25
? at 60 Hz0.28
closing delay
? at AC8 … 40 ms
opening delay
? at AC4 … 16 ms
arcing time10 … 10 ms
control version of the switch operating mechanismStandard A1 – A2
Auxiliary circuit
number of NC contacts for auxiliary contacts instantaneous contact2
number of NO contacts for auxiliary contacts instantaneous contact2
operational current at AC-12 maximum10:00 AM
operational current at AC-156:00 AM
● at 230 V rated value
● at 400 V rated value3:00 AM
● at 500 V rated value2:00 AM
● at 690 V rated value1:00 AM
operational current at DC-1210:00 AM
● at 24 V rated value
● at 48 V rated value6:00 AM
● at 60 V rated value6:00 AM
● at 110 V rated value3:00 AM
● at 125 V rated value2:00 AM
● at 220 V rated value1:00 AM
● at 600 V rated value0.15 A
operational current at DC-136:00 AM
● at 24 V rated value
● at 48 V rated value2:00 AM
● at 60 V rated value2:00 AM
● at 110 V rated value1:00 AM
● at 125 V rated value0.9 A
● at 220 V rated value0.3 A
● at 600 V rated value0.1 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor11:00 AM
● at 480 V rated value
● at 600 V rated value11:00 AM
yielded mechanical performance [hp] ● for single-phase AC motor1 hp
— at 110/120 V rated value
— at 230 V rated value2 hp
● for 3-phase AC motor3 hp
— at 200/208 V rated value
— at 220/230 V rated value3 hp
— at 460/480 V rated value7.5 hp
— at 575/600 V rated value10 hp
contact rating of auxiliary contacts according to ULA600 / Q600
Short-circuit protection
design of the fuse linkgG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA)
● for short-circuit protection of the main circuit
— with type of coordination 1 required
— with type of assignment 2 requiredgG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)
● for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
● side-by-side mountingYes
height85 mm
width45 mm
depth141 mm
required spacing10 mm
● with side-by-side mounting
— forwards
— upwards10 mm
— downwards10 mm
— at the side0 mm
● for grounded parts10 mm
— forwards
— upwards10 mm
— at the side6 mm
— downwards10 mm
● for live parts — forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side6 mm
Connections/ Terminals
type of electrical connectionscrew-type terminals
● for main current circuit
● for auxiliary and control circuitscrew-type terminals
● at contactor for auxiliary contactsScrew-type terminals
● of magnet coilScrew-type terminals
type of connectable conductor cross-sections ● for main contacts2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²)
— solid
— solid or stranded2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²)
— finely stranded with core end processing2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm²
● at AWG cables for main contacts2x (16 … 12), 2x (14 … 8)
connectable conductor cross-section for main contacts1 … 10 mm²
● solid
● stranded1 … 10 mm²
● finely stranded with core end processing1 … 10 mm²
connectable conductor cross-section for auxiliary contacts0.5 … 2.5 mm²
● solid or stranded
● finely stranded with core end processing0.5 … 2.5 mm²
type of connectable conductor cross-sections ● for auxiliary contacts2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²)
— solid or stranded
— finely stranded with core end processing2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²)
● at AWG cables for auxiliary contacts2x (20 … 16), 2x (18 … 14)
AWG number as coded connectable conductor cross section16 … 8
● for main contacts
● for auxiliary contacts20 … 14
Safety related data
product function
●                 mirror contact according to IEC 60947-4-1Yes No
●                 positively driven operation according to IEC 60947-5-1450 000
B10 value with high demand rate according to SN 31920 proportion of dangerous failures40%
●                 with low demand rate according to SN 3192073%
●                 with high demand rate according to SN 31920failure rate [FIT] with low demand rate according to SN 31920100 FIT
T1 value for proof test interval or service life according to IEC 61508 protection class IP on the front according to IEC20 a IP20
60529 touch protection on the front according to IEC 60529 suitability for usefinger-safe, for vertical contact from the front
● safety-related switching OFFYes
Weight0.460 kg
Dimensions5.40 × 9.2 × 14.9 cm