inosakiInosakiinosaki

Contact Us
sales@365accountings.com   

STEP-PS/ 1AC/12DC/1.5 – 2868567 – Phoenix Contact Power Supply

¥ 26,643.00

SKU: 2868567

Inosaki is one of the largest Phoenix Contact Distributors to provide terminal block, interface module, power supply and relay. And our best offer for terminal block types are Feed-through, Fuse Modular, Spring Cage, Double Level, and Multi-level, hence the series model references to  PT Series, ST Series, TB Series, UT Series, UK Series. In additional for power supply are QUINT Power, STEP Power, Trio Power, and UNO Power. Please email us for catalog: sales@365accountings.com

Product Description

STEP POWER power supplies for distribution boards
The STEP POWER power supply range was developed especially for building automation. The low idling losses and high degree of efficiency ensure maximum energy efficiency. They allow flexible use and can be snapped onto the DIN rail or screwed onto an even surface.

Dimensions

Width36 mm
Height90 mm
Depth61 mm
55 mm (Device depth (DIN rail mounting))
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom30 mm / 30 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C … 70 °C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport)-40 °C … 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2

Input data

Nominal input voltage range100 V AC … 240 V AC
Input voltage range85 V AC … 264 V AC
95 V DC … 250 V DC
AC frequency range45 Hz … 65 Hz
Frequency range DC0 Hz
Current consumption0.3 A (120 V AC)
0.2 A (230 V AC)
Nominal power consumption37.9 VA
Inrush current< 15 A (typical)
Mains buffering timetyp. 15 ms (120 V AC)
typ. 70 ms (230 V AC)
Input fuse1.25 A (slow-blow, internal)
Recommended breaker for input protection6 A … 16 A (Characteristics B, C, D, K)
Power factor (cos phi)0.57
Type of protectionTransient surge protection
Protective circuit/componentVaristor

Output data

Nominal output voltage12 V DC ±1 %
Nominal output current (IN)1.5 A (-25 °C … 55 °C)
1.65 A (-25°C … 40°C permanent )
Output current Imax2.6 A
Derating55 °C … 70 °C (2.5%/K)
Connection in parallelyes, for redundancy and increased capacity
Connection in seriesyes
Feedback voltage resistance≤ 25 V DC
Protection against overvoltage at the output (OVP)< 25 V DC
Control deviation< 1 % (change in load, static 10 % … 90 %)
< 2 % (change in load, dynamic 10 % … 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple< 75 mVPP (20 MHz)
Output power18 W
Typical response time< 0.5 s
Peak switching voltages nominal load< 10 mVPP (20 MHz)
Maximum power dissipation in no-load condition< 0.4 W
Power loss nominal load max.< 3.2 W

General

Article Number2868567
Net weight0.11 kg
Operating voltage displayGreen LED
Efficiency> 84 % (for 230 V AC and nominal values)
MTBF (IEC 61709, SN 29500)> 1800000 h (40 °C)
Insulation voltage input/output4 kV AC (type test)
3.75 kV AC (routine test)
Degree of protectionIP20
Protection classII (in closed control cabinet)
Housing materialPolycarbonate
Foot latch materialPOM (Polyoxymethylene)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: 0 mm horizontally, 30 mm vertically

Connection data, input

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length6.5 mm
Screw threadM3

Connection data, output

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length6.5 mm
Screw threadM3

Standards

EMC requirements for noise immunityEN 61000-6-1
EN 61000-6-2
EMC requirements for noise emissionEN 61000-6-3
EN 61000-6-4
Budgetary standardIEC 60335-1
Standard – Safety of transformersEN 61558-2-16
Standard – Electrical safetyIEC 62368-1 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageIEC 62368-1 (SELV) und EN 60204-1 (PELV)
Standard – Safe isolationDIN VDE 0100-410
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard – Approval for medical useIEC 60601-1, 2 x MOOP
Rail applicationsEN 50121-4

Conformance/approvals

UL approvalsUL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)
NEC Class 2 as per UL 1310
CSACSA-C22.2 No. 107.1-01
Shipbuilding approvalDNV GL (EMC B) ABS, NK

EMC data

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Electrostatic dischargeEN 61000-4-2
Contact discharge8 kV (Test Level 4)
Discharge in air8 kV (Test Level 3)
Electromagnetic HF fieldEN 61000-4-3
Frequency range80 MHz … 3 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A
Fast transients (burst)EN 61000-4-4
Input4 kV (Test Level 4 – asymmetrical)
Output2 kV (Test Level 3 – asymmetrical)
CommentsCriterion A
Surge voltage load (surge)EN 61000-4-5
Input2 kV (Test Level 3 – symmetrical)
4 kV (Test Level 4 – asymmetrical)
Output0.5 kV (Test Level 1 – symmetrical)
1 kV (Test Level 2 – asymmetrical)
CommentsCriterion A
Conducted interferenceEN 61000-4-6
Frequency range10 kHz … 80 MHz
Voltage10 V (Test Level 3)
CommentsCriterion A
Voltage dipsEN 61000-4-11
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration”

 