inosakiInosakiinosaki

Contact Us
sales@365accountings.com   

TeSys Deca – LC1D – 4 Poles (2 NO + 2 NC) Contactor, 32A – Schneider Contactors & Reversing Contactors

USD $ 21.63

SKU: LC1D188M7C

Schneider TeSys Deca series contactor LC1D188M7C, 4P (2NO+2NC) 32A, AC-1, 1NO+1NC aux contact, 220V 50/60Hz AC coil, screw wiring certification (IEC, CCC, CCS, RoHS, REACH).

Specifications

Main
Part NumberLC1D188M7C
Product SeriesTeSys Deca
Product SeriesTeSys Deca
product typeContactor
product short nameLC1D
Application field of contactorApplied to non-inductive or micro-inductive load, resistance furnace
use categoryAC-1
number of poles4P
Rated working voltage [Ue]Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 225 V DC
Rated operating current [Ie]32 A 60 °C) at <= 440 V AC AC-1 for power circuits
[Uc] control circuit voltage230V AC 50/60Hz
Additional information
modelLC1D
Loop contact type2 NO + 2 NC
protection capNone
Conventional thermal current [Ith]10 A at <60 °C for signal circuits
32 A at <60 °C for power circuits
Rated short-time withstand current [Icw]145 A at <40 °C – 10 s for power circuit
240 A at <40 °C – 1 s for power circuit
40 A at <40 °C – 10 min for power circuit
84 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
Fuses for use with relays10 A gG for signal circuits according to IEC 60947-5-1
50 A gG at <= 690 V for power circuits type 1
35 A gG for power circuits for type 2 at <= 690 V
average impedance2.5 mΩ – Ith 32 A 50 Hz for power loop
Rated insulation voltage [Ui]Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Overvoltage categoryIII
pollution level3
Rated impulse withstand voltage [Uimp]6 kV according to IEC 60947
Safety and reliability levelB10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
Mechanical life15 Mcycles
Electrical life1 Mcycles 32 A AC-1 <= 440 V at Ue
1.6 Mcycles 18 A AC-3 Ue <= 440 V
3 Mcycles 11 A AC-3 Ue at 660/690 V
Control loop characteristicsAC at 50/60 Hz
Surge Suppression ModuleNo built-in surge suppression module
Control voltage limit0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
(~50Hz pickup) power consumption (VA)70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
(~50Hz hold) power consumption (VA)7.5 VA 60 Hz 0.3 20 °C)
7 VA 50 Hz 0.3 20 °C)
heat dissipation2…3 W at 50/60 Hz
action time12…22 ms close
4…19 ms break
operating frequency3600 cycles/h at <60 °C
Wiring capacityControl circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals
control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal
control circuit: screw cable option1 1…4 mm² cable option : Solid without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Solid without wire terminals
Power circuit: Terminal 1 2.5…10 mm² Lug outer diameter Ø: 8 mm Cable selection Type: Flexible cord without wire terminals
Power circuit: Terminal 2 2.5…10 mm² Lug Ø: 8 mm Cable selection: Flexible cord without wire terminals
Power circuit: Terminal 1 2.5…10 mm² Lug Outer diameter Ø: 8 mm Cable option: Flexible cord with wire terminals
Power circuit: Terminal 2 2.5…10 mm² Lug outer diameter Ø: 8 mm Cable option: Flexible cord with bar terminals Power
circuit: Terminal 1 2.5…16 mm² O.D. lug Ø: 8 mm Cable option: Solid without cable terminals
Power circuit: Terminal 2 2.5…16 mm² Ø Lug: 8 mm Cable option: Solid without cable wire terminal
Tightening torqueControl circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screwdriver No 2 Phillips screw
power circuit: 1.8 Nm via screwdriver Ø 6 flat
power circuit: 1.8 Nm via screw Screwdriver No. 2 for fastening Phillips screw
Power circuit: 1.8 Nm Screwdriver Ø 6 Flat-blade screw via cable connector: M3.5 Power circuit
: 1.8 Nm Screwdriver No. 2 Phillips screw via cable connector Screw: M3.5
Power circuit: 1.8 Nm Tighten with screwdriver pozidriv No 2
Control circuit: 1.7 Nm Tighten with screwdriver pozidriv No 2
Auxiliary contact type1 NO + 1 NC
Auxiliary contact typeType Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1
Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1
Signal loop frequency25…400Hz
Minimum switching voltage17 V for signal return
Minimum switching current [Imin]5 mA for signal loop
Insulation resistance> 10 MΩ for signal loops
non-overlapping time1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
installation methodChassis mounting
rail installation
environment
standardGB 14048.4
IEC 60947-4-1
certified productCCC
CE
UKCA
IP protection classIP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
Protective measuresTH conforms to IEC 60068-2-30
ambient air temperature-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude3000 m None
Fire resistance and abnormal high temperature resistance850 °C conforming to IEC 60695-2-11
Shock and vibration resistanceShock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
high105 mm
width45 mm
depth99 mm
Product Weight0.425 kg
packaging unit
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.0cm
Package 1 Width9.3 cm
Package 1 Length5.2 cm
Package 1 Weight446.63g
Unit Type of Package 2CAR
Number of Units in Package 216
Package 2 Height30.0cm
Package 2 Width40.0cm
Package 2 Length15.0cm
Package 2 Weight7.196 kg
Unit Type of Package 3PAL
Number of Units in Package 3256
Package 3 Height60.0cm
Package 3 Width80.0cm
Package 3 Length75.0cm
Package 3 Weight114.536 kg
contract warranty
Warranty18 months

 

Weight0.425 kg
Dimensions9.9 × 4.5 × 10.5 cm

Title