inosakiInosakiinosaki

Contact Us
sales@365accountings.com   

TeSys T – Motor Controller – Modbus TCP/EtherNet/IP – Schneider Digitized Motor Starters

USD $ 501.48

SKU: LTMR100EFM

TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. Ethernet/IP and Modbus/TCP protocol is used by this controller. Ethernet TCP/IP communication is used. This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay. The current range of this controller is 5 to 100 amperes. 120 to 240 VAC is used to power this controller. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.

Specifications

Main
Part Number

LTMR100EFM

RangeTeSys
Product nameTeSys T
Device short nameLTMR
Product or component typeMotor controller
Device applicationEquipment monitoring and control
Measurement current5…100 A
[Us] rated supply voltage100…240 V AC 50/60 Hz
Current consumption8…62.8 mA
supply voltage limits93.5…264 V AC
Communication port protocolModbus TCP/EtherNet/IP
bus typeEthernet IEEE 802.3 interface, addressing 0…159, transmission rate 10…100 Mbit/s, RJ45 with 2 shielded twisted pairs
Complementary
[Ui] rated insulation voltage690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
[Uimp] rated impulse withstand voltage4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
short-circuit withstand100 kA conforming to EN/IEC 60947-4-1
associated fuse rating4 A gG for output
0.5 A gG for control circuit
protection typeReverse polarity protection
Overload
Phase unbalance
Overload (long time)
Thermal protection
Power factor variation
Thermal overload protection
Locked rotor
Earth-leakage protection
Load fluctuation
Phase failure
Network and machine diagnosis typeWaiting time after overload tripping
Motor control command recording
Trip context information
Phase fault and earth fault trip counters
Starting current and time
Trip history information
Fault recording
Event recording
Remaining operating time before overload tripping
Running hours counter/operating time
Logic input number6
input current3.1 mA at 100 V
7.5 mA at 240 V
current state 0 guaranteedLogic input: 0…40 V and <= 15 mA for 25 ms
current state 1 guaranteedLogic input: 79…264 V and >= 2 mA for 25 ms
maximum output switching frequency2 Hz
load current5 A at 250 V AC for logic output
5 A at 30 V DC for logic output
permissible power480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
Maximum operating rate1800 cyc/h
contacts type and composition1 NO + 1 NC fault signal
3 NO
Metering typePhase current I1, I2, I3 RMS
Temperature
Earth-fault current
Average current Iavg
Imbalance current
measurement accuracy5…15 % earth fault current internal measurement
1 % voltage (100…830 V)
3 % power factor
5 % earth fault current external measurement
+/- 30 min/year internal clock
0,02 temperature
5 % active and reactive power
0,02 current
Overvoltage categoryIII
Connection pitch5.08 mm
connections – terminalsControl circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) solid without cable end
tightening torqueControl circuit: 0.5…0.6 N.m flat screwdriver 3 mm
Pollution degree3
electromagnetic compatibilityElectrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Width91 mm
Height61 mm
Depth122.5 mm
Net weight0.53 kg
Web servicesWeb server
Compatibility codeLTMR
Environment
StandardsCSA C22.2 No 14
EN 60947-4-1
IACS E10
UL 508
IEC 60947-4-1
Product certificationsC-Tick
ABS
UL
DNV
NOM
RINA
RMRoS
BV
LROS (Lloyds register of shipping)
KERI
EAC
CCC
CSA
ATEX
GL
protective treatment12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068
fire resistance650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94
ambient air temperature for operation-20…60 °C
Ambient air temperature for storage-40…80 °C
operating altitude<= 2000 m without derating
mechanical robustnessVibrations mounted on symmetrical rail: 1 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6
Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
IP degree of protectionIP20
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.2 cm
Package 1 Width10.0 cm
Package 1 Length13.5 cm
Package 1 Weight538.0 g
Unit Type of Package 2S02
Number of Units in Package 210
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight5.685 kg
Contractual warranty
Warranty18 months

 

Weight0.53 kg
Dimensions12.25 × 9.1 × 6.1 cm

Title