inosakiInosakiinosaki

Contact Us
sales@365accountings.com   

UNO-PS/1AC/24DC/90W/C2LPS – 2902994 – Phoenix Contact Power Supply

USD $ 174.30

SKU: 2902994

Inosaki is one of the largest Phoenix Contact Distributors to provide terminal block, interface module, power supply and relay. And our best offer for terminal block types are Feed-through, Fuse Modular, Spring Cage, Double Level, and Multi-level, hence the series model references to  PT Series, ST Series, TB Series, UT Series, UK Series. In additional for power supply are QUINT Power, STEP Power, Trio Power, and UNO Power. Please email us for catalog: sales@365accountings.com

Product Description

UNO POWER power supplies with basic functionality
Thanks to their high power density, compact UNO POWER power supplies are the ideal solution for loads up to 240 W, particularly in compact control boxes. The power supply units are available in various performance classes and overall widths. Their high degree of efficiency and low idling losses ensure a high level of energy efficiency.

Dimensions

Width55 mm
Height90 mm
Depth84 mm
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom30 mm / 30 mm

Ambient conditions

Degree of protectionIP20
Inflammability class in acc. with UL 94 (housing / terminal blocks)V0
Ambient temperature (operation)-25 °C … 70 °C (> 55 °C Derating: 2.5 %/K)
Ambient temperature (start-up type tested)-25 °C
Ambient temperature (storage/transport)-40 °C … 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2

Input data

Nominal input voltage range100 V AC … 240 V AC
Input voltage range85 V AC … 264 V AC
AC frequency range50 Hz … 60 Hz
Frequency range (fN)50 Hz … 60 Hz 10 %
Current consumptiontyp. 1.8 A (100 V AC)
typ. 0.8 A (240 V AC)
Nominal power consumption206.6 VA
Inrush current< 40 A (typ.)
Mains buffering time> 25 ms (120 V AC)
> 100 ms (230 V AC)
Input fuse3.15 A (slow-blow, internal)
Recommended breaker for input protection6 A … 16 A (Characteristics B, C, D, K)
Power factor (cos phi)0.49
Type of protectionTransient surge protection
Protective circuit/componentVaristor

Output data

Nominal output voltage24 V DC ±1 %
Nominal output current (IN)3.75 A (-25 °C … 55 °C)
Derating55 °C … 70 °C (2.5%/K)
Connection in parallelno
Connection in seriesNo
Feedback voltage resistance≤ 35 V DC
Protection against overvoltage at the output (OVP)≤ 35 V DC
Control deviation< 1 % (change in load, static 10 % … 90 %)
< 3 % (Dynamic load change 10 % … 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Residual ripple< 45 mVPP (with nominal values)
Output power90 W
Typical response time< 1 s
Maximum power dissipation in no-load condition< 0.5 W
Power loss nominal load max.< 12 W

General

Article Number2902994
Net weight0.34 kg
Efficiencytyp. 88 % (120 V AC)
typ. 88 % (230 V AC)
MTBF (IEC 61709, SN 29500)> 1159000 h (40 °C)
Insulation voltage input/output4 kV AC (type test)
3 kV AC (routine test)
Degree of protectionIP20
Protection classII (in closed control cabinet)
Inflammability class in acc. with UL 94 (housing / terminal blocks)V0
Housing materialPolycarbonate
Foot latch materialPOM (Polyoxymethylene)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: 0 mm horizontally, 30 mm vertically

Connection data, input

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length8 mm
Screw threadM3

Connection data, output

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length8 mm
Screw threadM3

Standards

EMC requirements for noise immunityEN 61000-6-1
EN 61000-6-2
EMC requirements for noise emissionEN 61000-6-3
EN 61000-6-4
Standard – Safety of transformersEN 61558-2-16
Standard – Electrical safetyIEC 62368-1 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageIEC 62368-1 (SELV) und EN 60204-1 (PELV)
Standard – Safe isolationDIN VDE 0100-410
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Mains variation/undervoltageEN 61000-4-11

Conformance/approvals

UL approvalsUL/C-UL listed UL 508
NEC Class 2 as per UL 1310
UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)
UL/C-UL Recognized UL 60950-1
CSACAN/CSA-C22.2 No. 60950-1-07
CSA-C22.2 No. 107.1-01
CAN/CSA-C22.2 No. 213 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)

EMC data

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Electrostatic dischargeEN 61000-4-2
Contact discharge6 kV (Test Level 3)
Discharge in air8 kV (Test Level 3)
Electromagnetic HF fieldEN 61000-4-3
Frequency range80 MHz … 1 GHz
Test field strength10 V/m (Test Level 3)
Frequency range1 GHz … 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A
Fast transients (burst)EN 61000-4-4
Input4 kV (Test Level 4 – asymmetrical)
Output2 kV (Test Level 3 – asymmetrical)
CommentsCriterion B
Surge voltage load (surge)EN 61000-4-5
Input2 kV (Test Level 3 – symmetrical)
4 kV (Test Level 4 – asymmetrical)
Output1 kV (Test Level 2 – symmetrical)
2 kV (Test Level 1 – asymmetrical)
CommentsCriterion B
Conducted interferenceEN 61000-4-6
Frequency range10 kHz … 80 MHz
Voltage10 V (Test Level 3)
CommentsCriterion A
Voltage dipsEN 61000-4-11
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration”

Title

Go to Top